each of the choices below. When you arrive at the choice you want to make, move the
throttle to low position while that series of 5 tones are still being heard.
WARNING: the motor will run now by moving the throttlestick!
2. Battery type
(Voltage Cut-off)
NiCd:
. . . . .
2 Lipos: (5.8V)
.. .. .. .. ..
3 Lipos: (8.7V)
... ... ... ... ...
4 Lipos: (11.6V)
.… .… .… .… .…
5 Lipos: (14.5V)
.…. .…. .…. .…. .….
6 Lipos: (17.4V)
.….. .….. .….. .….. .…..
Following cell-setting only available in OPTO-Versions
7 Lipos: (20.3V)
.…... .…... .…... .…... .…...
8 Lipos: (23.2V)
.….... .….... .….... .….... .…....
9 Lipos: (26.1V)
.…..... .…..... .…..... .…..... .….....
10 Lipos: (29.0V)
.…...... .…...... .…...... .…...... .…......
3. Under voltage
reduces power when the battery gets low. -_ -_ -_ -_ -_
cuts off power when the battery getslow.
_- _- _- _- _-
4. Acceleration
Low:
V V V V V
Medium:
VV VV VV VV VV
High: VVV VVV VVV VVV VVV
5. Timing
Automatic: (7 ~ 30 degree) (recommended)
- - - - -
Soft: (7 degree) (2-pole motors)
-- -- -- -- --
Hard (22 ~ 30 degree) (multipole motors)
--- --- --- --- ---
6. Frequency
8 kHz: (recommended)
\ \ \ \ \
16 kHz
/ / / / /
Copyright 06/07 – Hacker Motor GmbH 3