background image

Specifications

Specifications are subject to change without notice.

Specification

Details

Dimensions (W x H x D) ½ DIN—144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)

Weight

1.7 kg (3.7 lb) (Controller weight without optional modules)

Enclosure

NEMA 4X/IP66 metal enclosure with a corrosion-resistant finish

Operating temperature

–20 to 60 °C (–4 to 140 °F); 

Cellular version

: –20 to 55 °C (–4 to 131 °F)

Storage temperature

–20 to 70 °C (–4 to 158 °F)

Relative humidity

0 to 95%, non-condensing

Altitude

2000 m (6562 ft) maximum

Installation category

II

Pollution degree

Protection class

I, connected to protective earth

Power requirements

100–240 VAC ±10%, 50/60 Hz; 0.5 A (7 Watt sensor load)

Measurement

Two device digital SC connectors

Relays high voltage

Two relays (SPDT); 

Maximum switching voltage

: 250 VAC; 

Maximum switching

current

: 5 A (resistive only load); 

Maximum switching power

: 1250 VA, 125 W

(resistive only load); 

Wire gauge

: 0.75 to 2.5 mm

2

 (18 to 12 AWG)

Outputs (optional)

Five 4–20 mA analog outputs on each analog output module

1

Analog input (0–20 mA or 4–20 mA) on each analog input module

Digital communication

Profibus DPV1 card

1

 (optional), Modbus TCP/IP

Network connection

2

LAN version

: Two Ethernet connectors (10/100 Mbps), switch function, M12 female D-

coding connector; 

Cellular version

 (optional): SIM card (3G/4G); 

WiFi version

(optional)

USB port

Used for data download and software upload. The controller records approximately
20,000 data points for each connected sensor.

Compliance information CE. ETL certified to UL and CSA safety standards (with all sensor types).

Warranty

1 year (EU: 2 years)

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer’s website.

1

Refer to the module documentation for additional information.

Note: Connect only one module to one of the available slots.

2

The type of connection is dependent on controller configuration.

English

   

3

Содержание SC4200c

Страница 1: ...DOC343 52 90586 SC4200c 06 2019 Edition 7 User Manual...

Страница 2: ......

Страница 3: ...er connections 14 Open the controller cover 14 Remove the high voltage barrier 14 Wiring for power 15 Connect conduit or a power cord 16 Connect the high voltage relays 17 Install an expansion module...

Страница 4: ...Cleaning the controller 29 Troubleshooting 29 LED status 29 Connection problems 30 Replacement parts and accessories 30 Table of Contents 2...

Страница 5: ...each analog output module1 Analog input 0 20 mA or 4 20 mA on each analog input module Digital communication Profibus DPV1 card1 optional Modbus TCP IP Network connection2 LAN version Two Ethernet co...

Страница 6: ...tially or imminently hazardous situation which if not avoided could result in death or serious injury C A U T I O N Indicates a potentially hazardous situation that may result in minor or moderate inj...

Страница 7: ...ansmitters N O T I C E This is a Class A product intended for use in an industrial environment In a domestic environment this product may cause radio interference in which case the user may be require...

Страница 8: ...si le brouillage est susceptible d en compromettre le fonctionnement United States FCC Contains RF Module FCC ID RI7LE910NAV2 or FCC ID RI7LE910SVV2 Modifications not expressly approved by this compan...

Страница 9: ...2 channel controller for digital sensors Refer to Figure 1 The controller is configured and operated with a Mobile sensor management MSM software The MSM software is accessible through a web applicati...

Страница 10: ...r 3 SIM card4 8 Electrical connections and fittings 4 Expansion module5 9 Cover for module installation 5 Additional expansion module slots 10 High voltage barrier 4 Dependent on controller configurat...

Страница 11: ...ation gasket for pipe mount 11 Pan head screws M5 x 0 8 x 15 mm 4x 5 Vibration isolation washer for pipe mount 4x 12 Pan head screws M5 x 0 8 x 100 mm 4x 7 6 Bracket for wall and pipe mounting 6 13 Sc...

Страница 12: ...0 m 6562 ft maximum Use of this instrument at an altitude higher than 2000 m can slightly increase the potential for the electrical insulation to break down which can result in an electric shock hazar...

Страница 13: ...ttach the controller upright to a pole or pipe horizontal or vertical Make sure that the pipe diameter is 19 to 65 mm 0 75 to 2 5 in Refer to the illustrated steps in Figure 4 and Product components o...

Страница 14: ...re to use the template in the up position to install the controller vertical Refer to Figure 5 Note If using the bracket optional for panel mounting push the controller through the hole in the panel a...

Страница 15: ...re 6 Electrical connectors and fittings 1 Strain relief fitting for relay 5 Digital SC connector Sensor 1 Channel 1 2 Strain relief fitting for modules 6 Digital SC connector Sensor 2 Channel 2 3 Ethe...

Страница 16: ...ds Only qualified personnel must conduct the tasks described in this section of the document D A N G E R Electrocution hazard Always remove power to the instrument before making electrical connections...

Страница 17: ...disconnect all the electrical current carrying conductors Mains connection must keep supply polarity The separable plug is the disconnect means for cord connected equipment W A R N I N G Electrical s...

Страница 18: ...pin type terminal on the end A power cable with a three prong plug with ground connection that is applicable to the supply connection Connected through a cable gland strain relief that holds the powe...

Страница 19: ...otective earth ground Green Green with yellow stripe Connect the high voltage relays D A N G E R Electrocution hazard Always remove power to the instrument before making electrical connections W A R N...

Страница 20: ...solated from each other and the low voltage input output circuitry The relay terminals accept 0 75 to 2 5 mm2 18 to 12 AWG wire as determined by load application Use wire with an insulation rating of...

Страница 21: ...IP Modbus TCP IP is a standard for industrial communications The Modbus TCP IP protocol connects computers to measurement and control systems that use the TCP IP protocol for data transmission This t...

Страница 22: ...controller cover Tighten the cover screws with a maximum torque of 1 4 Nm 12 4 in lb Refer to Figure 7 on page 14 Connect a digital sc sensor W A R N I N G Explosion hazard This manual is only for in...

Страница 23: ...e front panel has icons at the top that shows the controller condition Refer to Table 5 The sensor status LED shows the condition of each sensor Refer to Table 6 Refer to Troubleshooting on page 29 to...

Страница 24: ...e sensor on the other channel is connected Startup Connect the power cord to an electrical outlet with protective earth ground or set the circuit breaker for the controller to on Web server applicatio...

Страница 25: ...Connection then select Properties 3 Highlight Internet Protocol Version 4 TCP IPv4 then select Properties 4 Select Use the following IP address Enter the settings that follow Option Description IP add...

Страница 26: ...dition Versions Shows the software version of the controller Logs and History Shows the historical data i e configuration and log events of the controller Restart Sets the controller to off and on aga...

Страница 27: ...default gateway 7 Select Network connection sharing to share the internet connection of the instrument with other controllers Note When this setting is selected the two ports are switched together and...

Страница 28: ...IN SIM card PIN 8 Select Apply and wait until the message Modem is currently configured shows on the PC Note An internet connection is not necessary to complete this configuration 9 Remove the Etherne...

Страница 29: ...Diagnostic data of the controller Use the USB connection to download data from the controller As an alternative the data download procedure is also available through the user interface on the MSM sof...

Страница 30: ...s removed close the slot cover and tighten the cover screws Tighten the cover screws with a maximum torque of 1 4 Nm 12 4 in lb Figure 17 USB flash drive connection Set the SC sensors on hold Use the...

Страница 31: ...MSM and to the sensor user manual There is a communication failure between the sensor and the controller Examine the sensor and the sensor cable for damage If damage is found contact technical support...

Страница 32: ...ontroller to on again Contact technical support if the LED stays red again The cloud connection LED stays off Sometimes the LED flashes blue for a short time No access to internet Cellular internet ac...

Страница 33: ...9 00037 Mounting hardware with Sunroof LXZ524 99 00036 USB cover and screws SC4200c LXZ524 99 00032 Module holder SC4200c LXZ524 99 00017 Main board cover and wiring labels SC4200c LXZ524 99 00019 Set...

Страница 34: ...32 English...

Страница 35: ......

Страница 36: ...669 2932 orders hach com www hach com HACH LANGE GMBH Willst tterstra e 11 D 40549 D sseldorf Germany Tel 49 0 2 11 52 88 320 Fax 49 0 2 11 52 88 210 info de hach com www de hach com HACH LANGE S rl 6...

Отзывы: