Graphical display
The graph shows concentration and temperature measurements for each channel in use. The graph
supplies easy monitoring of trends and shows changes in the process.
1.
From the graphical display screen use the up and down arrow keys to select a graph and push
the
home
key.
2.
Select an option:
Option
Description
MEASUREMENT VALUE
Set the measurement value for the selected channel. Select between AUTO
SCALE and MANUALLY SCALE. For manual scaling enter the minimum and
maximum measurement values.
DATE & TIME RANGE
Select the date and time range from the available options.
System startup
When initially powered up, the LANGUAGE, DATE FORMAT and DATE/TIME screens appear in
order. After these options are set, the controller performs a device scan and displays the message
SCANNING FOR DEVICES. PLEASE WAIT...
If a new device is found, the controller performs an
installation process before displaying a main measurement screen.
If the scan finds previously installed devices without configuration changes, the main measurement
screen of the device in the number one position appears immediately after the scan is complete.
If a device has been removed from the controller or is not found during the next power-cycled or
menu-driven scan, the controller displays a
DEVICE MISSING
message and prompts to delete the
missing device.
If no sensor is connected to an installed analog module, the controller will indicate an error. If devices
are connected but not found by the controller, refer to the
Troubleshooting
section of this manual.
Set the language, date and time for the first time
The controller displays the language, date and time edit screens when the controller is powered on
for the first time, and when it is powered on after the configuration settings have been set to their
default values.
After the language, date and time options are set for the first time, update the options as necessary
through the setup menu.
1.
In the LANGUAGE screen, highlight a language in the options list and push the
enter
key.
English is the default language for the controller.
2.
In the DATE FORMAT screen, highlight a format and push the
enter
key.
3.
In the DATE/TIME screen, push the
right
or
left
arrow keys to highlight a field, then push the
up
and
down
arrow keys to update the value in the field. Update the other fields as necessary.
4.
Push the
enter
key. The changes are saved and the controller performs a start-up scan for
devices. If connected devices are found, the controller displays the main measurement screen for
the device in the number one position. If the controller fails to find connected devices, refer to the
Troubleshooting
section of this manual.
Controller configuration information
General information about configuration options is listed in the table.
1.
Push the
menu
key and select Polymetron 9500 SETUP.
Option
Description
SECURITY SETUP
Sets the passcode preferences.
OUTPUT SETUP
Configures the controller analog outputs.