![Hach POLYMETRON 9135 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/hach/polymetron-9135/polymetron-9135_operators-manual_577103042.webp)
Transmitter 9135 - pH/redox measurement
Page 38
PARAMETERS Menu
The date, slope and zero of the last calibration may
be displayed in the PARAMETER menu.
HISTORIC Menu
The slope and zero parameters of the last two
calibrations may be displayed in the historic menu.
Press the left function key SELECT to display the
next parameters.
MAINTENANCE Menu
When changing an electrode or servicing the
instrument, the transmitter continues to display
measures.
Note :
The analogue output value is the value
programmed in the mA menu. The relay state is
not modified.
DATE
: 26/03/96
SLOPE : 95%
ZERO
: 0,3 pH
∆
T
: 0,2°C
PARAMETER
DATE
: 26/03/96
SLOPE : 98%
ZERO
: -0,3 pH
HISTORIC
Select.
6.98
pH
26.4 °C
MAINTENANCE