L-80-00043-SCCC  Rev 01 

 

User Guide 

LightDeck MINI System 

 

 

 

Please see the test cartridge package insert for test-specific information.  

 

Software version 1.0 or greater 

 

 

Содержание LightDeck MINI

Страница 1: ...L 80 00043 SCCC Rev 01 User Guide LightDeck MINI System Please see the test cartridge package insert for test specific information Software version 1 0 or greater ...

Страница 2: ...nings 3 LightDeck MINI Overview 4 Installation 4 LightDeck MINI Front Back and Bottom Views 4 Instrument Label 5 LightDeck MINI Specifications 5 Calibration 5 Navigation 5 Import Lot Specific Calibration Data with New Cartridge Lots 6 RUN TEST 7 Start instruments and software 7 Test Procedure 7 Read cartridge 8 VIEW DATA 10 Maintenance and Cleaning 12 How to Clean Outside Surfaces 12 Troubleshooti...

Страница 3: ...acture Do NOT recycle In compliance with European Directive 2002 96 EC on waste electrical and electronic equipment WEEE this equipment must not be disposed of as unsorted municipal waste Instead it must be collected separately in accordance with local recycling regulations Presence of the symbol indicates that compliance must be adhered to for this device on waste electrical and electronic equipm...

Страница 4: ......

Страница 5: ... conditions required for proper use of this product e g power supply installation environment described in this manual 5 LightDeck Diagnostics shall not be liable for malfunctions and damage resulting from natural disasters such as fires earthquakes and floods The LightDeck MINI is used with LightDeck test cartridges to perform immunoassays Description The LightDeck MINI is an automated fluorescen...

Страница 6: ...ths used for cleaning equipment are potentially infectious waste and disposal must follow applicable local state or federal regulations When discarding the LightDeck MINI that may be contaminated with sample disposal must follow applicable local state or federal regulations Electrical Hazards Use only the power supply included with the LightDeck MINI The power supply voltage applied to the equipme...

Страница 7: ...ened when a cartridge is not present If the enclosure is damaged immediately stop using the LightDeck MINI to prevent possible exposure to hazardous laser radiation Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Other Safety Warnings EXPLOSIVE HAZARD Do not use flammable and explosive gas around the e...

Страница 8: ...s signs of damage Report any damage immediately 2 Install the software from the USB flash drive supplied with the LightDeck MINI 1 Insert the USB flash drive in the computer 2 Double click on the installation file 3 Follow the installation procedure as directed by the software 4 Plug in the power sources for the computer and LightDeck MINI 5 Attach USB cable from the LightDeck MINI to the computer...

Страница 9: ... Storage humidity 5 95 non condensing Altitude 0 2000 m Weight 3 5 pounds 1 5 kg Physical dimensions 4 4 W x 5 9 H x 6 1 L inches 112 W x 150 H x 155 L millimeters Calibration The LightDeck MINI is factory calibrated No user calibration or verification required Software Interface The Home Screen lets you navigate to modules to run sample or quality control tests to view stored sample results or QC...

Страница 10: ... from the internet by following the prompts in the LightDeck T software 1 Turn on the computer 2 Start LightDeck T software by double clicking the LightDeck T icon on the desktop to launch the software 3 Import the calibration file 4 Select IMPORT 5 Navigate to the USB drive Double click the xxx cdf xml file Alternatively select INTERNET to download the file 6 Select Update Now to import the calib...

Страница 11: ...tware 3 Double click the LightDeck T icon on the desktop to launch the software Test Procedure Click the RUN TEST button Enter sample information Choose a test from the drop down menu Enter Sample Information Click ACCEPT to load your inputs Open the pouch Remove the test cartridge Avoid touching the clear plastic on the bottom of the test cartridge Label the test cartridge with a sample ID Cautio...

Страница 12: ... using the pipette depress the plunger fully before aspirating Add sample to cartridge Dispense 100 L combined sample and reagents into the sample port of the test cartridge Read cartridge Open cartridge door Click READY to open the test cartridge door Tip The door will automatically close after 30 seconds so click Ready when you are ready to insert the test cartridge If the door closes just click...

Страница 13: ...ormation Test Processing The rest of the test is automatic For most test cartridge types the processing time is 10 minutes Test Complete Results are displayed Click DONE to release the cartridge and remove it from the LightDeck MINI Export Test Results If a PDF report for the sample is desired click VIEW DATA select samples to export and click EXPORT ...

Страница 14: ...ts and archive samples Click VIEW DATA Select PDF Summary to export data as pdf files Select Excel Spreadsheet to export data in a spreadsheet format You may configure the table to show multiple columns Click on Select Columns then click on the field and then click on the arrow to move it ...

Страница 15: ...able to show archived samples in the summary table EXPORT Click on the format for the export operation You can choose the fields to include in your spreadsheet Click PDF Summary for a summary table of the selected samples similar to the table shown on the screen Click PDF Summary and Individual Files for a multi page PDF with a report for each sample selected Click Excel Spreadsheet for an Excel f...

Страница 16: ...g a new cartridge Unable to read the cartridge barcode Barcode not read Verify that barcode is not damaged and retry If error persists select a new cartridge The inserted cartridge is of an unknown test type Cartridge Definition File not loaded Load the Calibration Info for the cartridge lot using the USB drive provided in the test cartridge box Wrong Cartridge Inserted Do you wish to proceed Cart...

Страница 17: ...run the sample using a new cartridge High Internal Positive Control Flow control reading high Re run the sample using a new cartridge Reference Spot Not Found Reagent pellet error Re run the sample using a new cartridge Dried Reagents Not Added or Cartridge Not Punctured Reagent pellet error or cartridge error Re run the sample using a new cartridge Cartridge Hold Failure Cartridge error Re run th...

Страница 18: ...Appendix 14 ...