Lorenz Hasenbach GmbH u. Co. KG · D-65517 Bad Camberg · Tel. 0049 6434 / 25-0 · www.haca.com
Harness selection
The safety harness must comply with EN 361. A risk as-
sessment must be performed according to the respective
applicable national regulations and laws of the country
of use. The selection of the harness depends on the requirements of
the assignment. HACA fall arrest systems are intended for climbing.
The safety harness must have suitable attachment points for the
designated use. The connecting element of the guided type fall ar-
rester has to be attached to the front eyelet respectively loop of the
harness (marking A) in order to guarantee the use in accordance
with EN 353-1. If the harness becomes loose during ascending it has
to be retightened in a safe position. The operating instructions of
the harness manufacturer must be heeded. Only safety harnesses
without elastic harness straps may be used.
The fall protection runner may only be used as intended. The climbing path is
only to be used to overcome differences in height. It is not permitted to work
on the ladder using the fall protection runner! While working on the ladder
the operator has to secure himself additionelly with a separate system, e.g.
safety rope according to DIN 358. The HACA fall protection system is designed
for one person to be on the ladder for each 4 m of the climb. When more
than one person is using the equipment, we dictate that a safety distance of
at least 3m is maintained. For fall arrest systems, it is essential to ensure that
the position of the anchorage device / anchorage point minimises free fall.
All further applications other than those approved by the manufacturer are
forbidden. Alterations or additions to the fall protection runner may not be
made without the written consent of HACA. Repairs may only be conducted
by HACA or by a dealer authorised by HACA. The fall protection runners can
be used at temperatures of between -40°C and +50°C.
The user must satisfy both the physical and the technical prerequisites. The
physical prerequisites are generally considered to have been proven if, for ex-
ample, a G41 medical check-up has been carried out. In addition to this the
current condition of health must always be taken into consideration. In
order to rule out danger to the user resulting from reduced physical fitness,
climbing must be restricted to users who are physically fit and are suited to
do so.
The technical prerequisites are based on information in these Instructions for
Use and a training course on using the fall protection runner.
The fall protection runner is a component of the PPE (Personal Protective
36
.Lorenz Hasenbach GmbH u. Co. KG · D-65517 Bad Camberg · Tel. 0049 6434 / 25-0 · www.haca.com
Содержание 0529.74.50
Страница 23: ...MA 5050 D UK d 23 Deutsch Lorenz Hasenbach GmbH u Co KG D 65517 Bad Camberg Tel 0049 6434 25 0 www haca com...
Страница 28: ...28 Lorenz Hasenbach GmbH u Co KG D 65517 Bad Camberg Tel 0049 6434 25 0 www haca com 16 Grund der Bearbeitung...
Страница 29: ...MA 5050 D UK d 29 Deutsch Lorenz Hasenbach GmbH u Co KG D 65517 Bad Camberg Tel 0049 6434 25 0 www haca com...
Страница 32: ...32 Lorenz Hasenbach GmbH u Co KG D 65517 Bad Camberg Tel 0049 6434 25 0 www haca com...
Страница 33: ...MA 5050 D UK d 33 English Lorenz Hasenbach GmbH u Co KG D 65517 Bad Camberg Tel 0049 6434 25 0 www haca com...
Страница 64: ...64 Lorenz Hasenbach GmbH u Co KG D 65517 Bad Camberg Tel 0049 6434 25 0 www haca com...