Oil-change interval and lubricant quantity
Lubrication
«for life»
(assuming pollution-free environment)
Worm
gear reducers
sizes
100 ... 250
.
The oil quantity is given by the level stated by the proper plug or an equivalent system
(plug for flowing over level, plug with dipstick).
Lubrication «
for life
» (assuming pollution-free environment).
Oil
Oil-change
temperature [°C]
interval [h]
0 0
65
9 000
65
80
6 300
80
95
4 500
Oil
Oil-change interval [h]
temperature [°C]
65
12 500
65
80
)
9 000
80
95
)
6 300
An overall guide to
oil-change interval
is given in the table, and assumes pol-
lution-free environment. Where heavy overloads are present, halve the values.
Apart from running hours replace or regenerate synthetic oil at least each 5
years.
The oil quantity is given by the level stated by the proper plug or an equi-
valent system (plug for flowing over level, plug with dipstick).
An overall guide to
oil-change inter-
val
is given in the table, and assumes
pollution-free surroundings. Where
heavy overloads are present, halve
the values.
Apart from running hours, replace or
regenerate the oil each 5 years.
Coaxial
gear reducer sizes
100 ... 180
.
Parallel
and
right angle shaft
gear reducer sizes