Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Fax. ++39(0)438.200545
PM-304 Press Bank
Author:
S.D.T. / KM
OPERATION
Edition: 02/2005
Page
D-10
Replaces: 01/2002
D.4.5
Irregular stopping of the joining cycle
NOTE
If the cooling cycle is stopped before the end the circuit, it will not discharge all the water of the system.
This may jeopardize the next joining cycle with resulting defective joints.
In this case it is necessary to act as follows:
Turn the switch on the PMR-06 regulating unit to “ON”.
Push the “START” button to start the joining cycle.
As soon as you have pushed the “START” button press the “STOP JOINING CYCLE” button. This starts
the cooling procedure that finally expels the water from the cooling circuit.
Refer to the operating instructions of regulating unit PMR-06 for further details.
D.4.6
Indicator lights
There are indicator lights for each press showing their status.
These lights are green and red and indicate the following:
GREEN
PMR-06/PMC-06/PM-304 in standard working mode
continiously
RED
PMR-06/PMC-06/PM-304 in alarm mode;
continiously
a serious condition stopped the joining cycle
RED and GREEN
PMR-06/PMC-06/PM-304 in warning mode;
flashing together
there is a problem present but the joining cycle is not stopped
D.4.7
Technical assistance
Our experts will be available for you to consult on the use of the machine. If you have any technical
queries regarding the operation and the status of the joining device, contact the manufacturer (see
address in
PM-304 Press Bank