Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Fax. ++39(0)438.200545
Hot Press PM-1306
Author:
S.D.T. / KM
OPERATION
Edition: 02/2005
Page
D-13
Replaces: 01/2002
D.5.4
Mobile operation use
Check the working procedures for the belt/tape, check technical guidelines of the joining method and the
individual Joining Data Sheet of the product.
Open the two locking spindels (4), flip them downwards and lift the upper part of the press (1). When
opening the rods make sure not to put them down heavily on the floor or supporting surface.
Position the belt as required on the heat equilazing plate (8) and clamp it, making sure it is flat.
Position the upper part of the press (1) onto the lower part of the press (6) with the belt fastened to the
heat equalizing plate (8) and the required inserts.
Flip back the two locking spindles (4) and evenly lock them at the two ends of the press.
Ensure there is no liquid in the cooling circuit. This happens when the normal joining cycle is stopped
(either deliberately or due to a black-out for example) during the cooling stage.
In this case it is necessary to act as follows
:
Disconnect all electrical supply.
Disconnect the tubes of the press.
Empty the cooling circuit using jets of compressed air.
When blowing air to expel water from the circuit, make sure the water does not come into contact with
electrical equipment.
Use the portable compressor MC-04/x to bring the pressure cushion to the desired pressure.
Use the regulating unit PMR-XX (see its own manual) to preselect the hot-pressing device's upper and
lower temperatures.
Use the regulating unit PMR-XX (see its own manual) to select the joining time.
Use the regulating unit PMR-XX (see its own manual) to start the joining cycle.
At the end of the joining cycle (see control equipment manual), it is necessary to manage the cooling of
the hot-pressing device manually.
For this purpose connect the flexible water hose for the mobile cooler PM-04/x to the water-hose
coupling (5) of the hot-pressing device and then start the electric pump (see 1.3.1
Wait for the end of the set cooling cycle.
Empty the air out of the pressure cushions.
Open hot-pressing device, carefully take out the belt and allow it to cool at room temperature.
Hot-pressing device PM-1306