9.1.9. Contrast brightness display
main menu
Procedure:
The required value can be selected with the
"Plus"
or
"Minus"
buttons.
The setting is saved by pressing the
"OK"
button.
To exit the function, press the
"On/Off"
button.
date/time
language
english
heating curve
contrast
OK
9.1.10. Software version information
Info Software
Procedure:
To exit the function, press the
"On/Off"
button.
Software: HSP-6-V5.03
test date: 2015-02-11
9.1.11. Test setting
Test setting
Heating in the test position is only permitted by specialists of
various test laboratories!
In this menu, the partial load / nominal load is tested according to
EN 14785 standard.
Procedure:
Use the
"Plus"
or
"Minus"
keys to enter the required code.
accese code
" * "
OK
The code is as follows:
1854
Pressing the
"OK"
button saves the setting.
The test setting partial load or nominal load is then selected.
Pressing the
"OK"
button activates the
"START"
of the respective test setting.
Typ
Chimney draft at nominal heat output / partial load
HSP 1, HSP 2
11 / 7 Pa
HSP 6
11 / 5 Pa
HSP 7
12 / 6 Pa
HSP 8
11 / 6 Pa
10. Oper. modes
10.1. Start zone 1-20 (start zone)
The start zone begins if:
• the current room temperature falls below the set target temperature by 1 °C
• the stove is cooled down to a temperature below 70 °C