General Safety Notes
6
Periodic maintenance of machine safety features:
•
Inspect door interlock mechanism for proper fit and function.
•
Inspect safety windows and enclosure for damage or leaks.
•
Verify all enclosure panels are in place.
Door Safety Interlock maintenance:
•
Inspect the door interlock, verify the door interlock key is not bent, misaligned, and
that all fasteners are installed.
•
Inspect the door interlock itself for any signs of obstruction or misalignment.
•
Immediately replace an components of the Door Safety Interlock system that do not
meet this criteria.
Door Safety Interlock testing:
•
With the machine in run mode, close the machine door, run the spindle at 100 RPM,
pull the door and verify the door does not open.
Machine Enclosure and Safety Glass maintenance and testing:
Routine Maintenance:
•
Visually inspect the enclosure and safety glass for any signs of distortion, breakage
or other damage.
•
Replace the Lexan windows after 7 years or if they are damaged or severely
scratched.
•
Keep all safety glass and machine windows clean to allow proper viewing of the
machine during operations.
•
A daily visual inspection of the machine enclosure to verify all panels are in place
should be performed.
Testing of machine enclosure:
•
No testing of the machine enclosure is necessary.
Содержание UMC-1000
Страница 2: ......
Страница 10: ...viii ...
Страница 16: ...How to Use This Manual xiv ...
Страница 36: ...Safety Decals 18 ...
Страница 40: ...UMC 1000 Specifications 22 ...
Страница 44: ...Machine Rotary Zero Point MRZP Offsets 26 ...
Страница 50: ...G234 Tool Center Point Control TCPC Group 08 32 ...
Страница 64: ...247 Simultaneous XYZ Motion in Tool Change 46 ...
Страница 70: ...52 ...