6. Decommissioning
Press the On/Off key (52) on the release module RM02 briefly to switch off the LED
illumination after the examination. This does not switch off the camera. This is sig‑
naled with pulsing green flashing. Pressing the key for approx. 3 sec. switches off
the release module completely and the operational control LED (51) goes out. The
camera has no separate On/Off switch. It switches off automatically when the PC is
switched off.
NOTE!
The On/Off key on the release module RM02 does not disconnect the
device from the electric mains. Disconnect the power supply from the
power grid by unplugging the mains connector if you do not intend to
use it for an extended period of time.
7. Technical data
7.1 Power supply
Type
ICCNEXERGY, ELPAC POWER SYSTEMS,
Model
MWA030018B‑10A
REF 1022106
Mains voltage
100 − 240 V
Current consumption 0.8 A
Operating frequency
50 − 60 Hz
7.2 Dimensions
Camera module CM02 / CM02BP
Weight:
2.6 kg (incl. packaging)
Dimensions L × W × H: 190 × 127 × 76 mm
Packaging L × W × H: 380 × 270 × 130 mm
7.3 Minimum PC requirements
Processor type
Intel i5, 5th gen or higher with 4 cores.
Note: 6th gen is not recommended.
2 cores with hyperthreading are not
recommended.
RAM
8 GB RAM if PC is exclusively used to operate the imag‑
ing module.
16 GB RAM if third‑party applications such as patient ad‑
ministration software are to be used alongside EyeSuite.
Use 2 RAM module.
Hard disk
At least 500 GB (NTFS data system).
Graphics
Graphics card with at least 2 GB memory (Nvidia or AMD
chip set recommended).
OpenGL 2.0
Monitor
At least 19", 1920 × 1080 pixel resolution.
Operating system
Windows 7, Windows 8.1, Windows 10.
64‑bit system only.
PCI slot
PCI‑Express 3.0
PCI Express card
Chip set by Renesas / NEC.
7.4 Camera
Camera beam:
Beam path right (from the point of view of the doctor)
Interface:
USB 3.0
Frame rate:
20 fps (frames per second)
Power consumption:
5 V
/ 300 mA
8. Maintenance
WARNING!
Do not modify this equipment without authorization of the manufacturer.
Installation and repairs may only be performed by trained specialists.
Contact your Haag-Streit representative for installation, repairs and
modification work on the system. The contact details are available at
www.haag-streit.com.
Only original Haag-Streit replacement parts may be used.
•
•
8.1 Device inspection
To check the correct function, proceed as follows:
•
Insert the test piece in the radial movement bearing, while aligning the surface at
a right‑angle to the Microscope
•
Set the slit length to 8 or 14mm
•
Illumination intensity to 50%
•
Set the magnification of the Microscope to max.
•
Set the ocular so that the structure on the test piece is shown in focus. In doing
so, turn the ocular from the (+) to the (‑) side.
•
Switch on camera
•
For all magnifications, the structure of the test piece in the ocular and in the cam
‑
era image must be sharply imaged