7
Figure 13 Using a power adapter to connect the AP to a local power source
Connecting a DC remote power
No terminal block is provided with the AP. Order as required.
As a best practice, should use 20AWG copper wire.
The output voltage range for the AP is 40 VDC to 55 VDC.
To connect a local DC power source:
1.
Insert a flat-head screwdriver straight into a square-shaped hole in the terminal block.
This will open the round-shaped hole above the square-shaped hole.
2.
Peel 10 mm (0.39 in) of sheath for one wire. Hold the screwdriver and insert the wire into the
round-shaped hole in the terminal block.
Identify the positive and negative feed positions. The wiring sequence is positive to positive
and negative to negative.
3.
Take out the flat-head screwdriver from the square-shaped hole.
The round-shaped hole will close, and the wire will be secured in place.
4.
Repeat the procedure to attach the other wire into the terminal block.
Figure 14 Connecting a local DC power source
Содержание WA6120H
Страница 8: ...2 Figure 2 Installation tools...
Страница 21: ...i Contents Appendix A Technical specifications 1...
Страница 23: ...i Contents Appendix B Ports and LEDs 1 Ports 1 LEDs 3...