2
Solution
To resolve the problem:
1.
Verify that you can access the CLI after the switch reboots.
{
If you can access the CLI, execute the
display diagnostic-information
command to
collect operating information.
{
If you cannot access the CLI, go to step
2
.
2.
Verify that the system software image on the switch is correct.
Connect to the switch through the console port and restart the switch. If BootWare reports that
a CRC error has occurred or that no system software image is available, perform the following
steps:
a.
Use the BootWare menu to reload the system software image.
b.
Configure it as the current system software image.
3.
If the problem persists, contact H3C Support.
Operating power module failure
Symptom
A trap or log is generated indicating that an operating power module is faulty.
Troubleshooting flowchart
Figure 2 Troubleshooting operating power module failure