58
Item S6520X-26MC-UPWR-SI
S6520X-26XC-UPWR-SI
S6520X-54XC-UPWR-SI
port
QSFP+ port
N/A
N/A
4
5G/2.5G/10
00/100BAS
E-T
autosensing
Ethernet
port
24 N/A
N/A
10G/5G/2.5
G/1000/100
BASE-T
autosensing
Ethernet
port
N/A 24 48
Expansion
slot
1, on the rear panel
Power
module slot
2, on the rear panel
Fan tray slot N/A
2
3
Input
voltage
PSR360-56A/PSR720-56A:
•
Rated voltage range: 100 to 240 VAC @ 50/60 Hz
•
Max voltage range: 90 to 264 VAC @ 47 to 63 Hz
PSR1110-56A:
•
Rated voltage range: 115 to 240 VAC @ 50/60 Hz
•
Max voltage range: 102.5 to 264 VAC @ 47 to 63 Hz
PSR560-56D:
You can use a –48 VDC power source in the equipment room or an H3C RPS (RPS1600-A)
for the PSR560-56D power module.
•
Rated voltage range: –48 VDC to –60 VDC
Max voltage range: –36 VDC to –72 VDC
Typical
power
consumptio
n (30% flow,
tested as
required by
CQC)
97 W
90 W
165 W
Maximum
power
consumptio
n (100%
flow and
fans at full
speed)
Non-PoE: 126 W
PoE: 2428 W (including 2040
W for PoE)
Non-PoE: 148 W
PoE: 2385 W (including
2010 W for PoE)
Non-PoE: 232 W
PoE: 2333 W (including 1920
W for PoE)
Chassis
leakage
current
compliance
UL60950-1/EN60950-1/IEC60950-1/GB4943.1
Melting
current of
power
module fuse
•
PSR360-56A: 6.3 A/250 V
•
PSR720-56A: 15 A/250 V
•
PSR1110-56A: 15 A/250 V
•
PSR560-56D: 30 A/75 V
Содержание S6520X-SI Series
Страница 8: ...iii Appendix D Cooling system 81...
Страница 48: ...40 1 2 3 4 5 6 7 8 9...
Страница 90: ...82 Figure 76 Airflow direction S6520X 26C SI...