background image

 

4-18 

Figure4-1 SFP+ cable 

 

(1) SFP+ module 

(2) Pull latch 

 

 

NOTE: 

  As a best practice, use H3C transceiver modules and network cables for the switch. 

  The H3C transceiver modules and network cables are subject to change over time. For the most 

recent list of H3C transceiver modules and cables, contact H3C Support or marketing staff. 

  For the specifications of H3C transceiver modules and network cables, see 

H3C Transceiver 

Modules User Guide

.

 

 

SFP28 port 

An LSWM2ZSP2P interface card provides SFP28 ports. To connect peer SFP28 ports over a long 
distance, use SFP28  transceiver modules and fibers. To connect peer SFP28  ports  over  a short 
distance, use SFP28  cables. You can install SFP28  transceiver modules in 

Table4-8

  and SFP28 

cables in 

Table4-9

 in the SFP28 ports. 

Table4-8 SFP28 transceiver modules available for the SFP28 ports 

SFP28 
transceiver 
module 

Central 
wavelength 
(nm) 

Connector 

Fiber type and 
diameter (µm) 

Modal 
bandwidth 
(MHz × km) 

Max 
transmission 
distance 

SFP-25G-LR-
SM1310 

1310 

LC 

Single-mode, 
9/125 

N/A 

10 km (6.21 miles) 

SFP-25G-SR-
MM850 

850 

LC 

Multi-mode, 
50/125 

2000 

70 m (229.66 ft) 

4700 

100 m (328.08 ft) 

 

Table4-9 SFP28 cables available for the SFP28 ports 

SFP28 cable 

Max transmission distance 

SFP-25G-D-CAB-1M 

1 m (3.28 ft) 

SFP-25G-D-CAB-3M 

3 m (9.84 ft) 

SFP-25G-D-CAB-5M 

5 m (16.40 ft) 

SFP-25G-D-AOC-3M 

3 m (9.84 ft) 

1

2

Содержание S5560X-HI Series

Страница 1: ...H3C S5560X HI Switch Series Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W102 20201116...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of op...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...nnecting the power cord for a PSR450 12D power supply 2 22 Installing and removing an expansion module 2 23 Installing an expansion module 2 23 Removing an expansion module 2 25 Verifying the installa...

Страница 7: ...ii Solution 5 43 Fan tray failure 5 43 Configuration terminal display issues 5 43 No display 5 43 Garbled display 5 44...

Страница 8: ...pply To avoid electrical shocks do not open the chassis while the switch is operating or when the switch is just powered off During switch installation wear an ESD wrist strap Make sure the strap make...

Страница 9: ...0 6 particles m 3 Dust particles 5 m 3 10 4 particles m 3 Dust suspension 75 m 0 2 mg m 3 Dust sedimentation 75 m to 150 m 1 5 mg m 2 h To maintain cleanliness in the equipment room follow these guide...

Страница 10: ...or gasoline engines separately Do not place them in the same equipment room with the device Make sure the exhausted air of the engines will not flow into the equipment room or towards the air inlet of...

Страница 11: ...irectly with optical instruments when the switch is operating The switch is a Class 1 laser device Installation tools No installation tools are provided with the switch Prepare the following tools you...

Страница 12: ...ng the switch CAUTION Keep the tamper proof seal on a mounting screw on the chassis cover intact and if you want to open the chassis contact H3C for permission Otherwise H3C shall not be liable for an...

Страница 13: ...2 6 Figure2 1 Hardware installation flow...

Страница 14: ...cuit breakers Operating correctly Turn off the circuit breakers Troubleshoot the switch No Yes End Connect interface cables Ground the switch Install fan trays Install power supplies Install expansion...

Страница 15: ...ck Rack with a depth in the range of 355 521 mm 13 98 20 51 in With the wide flange of the rear mounting brackets outside the rack Rack with a depth in the range of 199 365 mm 7 83 14 37 in The distan...

Страница 16: ...ing procedure attaches the front mounting brackets to the installation position near the power supply side The port side mounting is similar To attach the front mounting brackets and shoulder screws t...

Страница 17: ...he rear mounting brackets to the rack 1 Determine the switch installation position in the rack 2 Install cage nuts user supplied in the rear rack posts Make sure the corresponding cage nuts on the lef...

Страница 18: ...ith the wide flange outside the rack Mounting the switch in the rack The procedure is the same for using front mounting brackets A or B to rack mount the switch Front mounting brackets B is used as an...

Страница 19: ...holds the front part of the chassis with the other and pushes the chassis into the rack gently Make sure the shoulder screws rest firmly on the upper edge of the rear mounting brackets See Figure2 9 a...

Страница 20: ...h dry cloth 3 Attach the rubber feet to the four round holes in the chassis bottom 4 Place the switch with upside up on the workbench Grounding the switch WARNING Correctly connecting the grounding ca...

Страница 21: ...nal of the grounding cable to the grounding screw hole Fasten the screw IMPORTANT Orient the grounding cable as shown in Figure2 11 so that you can easily install or remove the removable components Fi...

Страница 22: ...o the earth ground to serve as a grounding conductor The dimensions of the angle iron must be a minimum of 50 50 5 mm 1 97 1 97 0 20 in The steel tube must be zinc coated and its wall thickness must b...

Страница 23: ...e is red The FAN 40F 1 A fan tray provides power supply side intake and port side exhaust airflows The fan tray handle is blue The FAN 40B 1 A fan tray provides port side intake and power supply side...

Страница 24: ...fan tray WARNING To avoid bodily injury disturbing the dynamic balance of the fan tray and causing loud noises do not touch the rotation axis or any bare wires fan blades or terminals on the fan tray...

Страница 25: ...le for the switch see removable power supplies in Hardware Information and Specifications Installing a power supply The installation procedures are the same for the PSR250 12A PSR250 12A1 and PSR450 1...

Страница 26: ...clicks into the slot To prevent damage to the power supply or the connectors on the backplane insert the power supply gently If you encounter a hard resistance when inserting the power supply pull out...

Страница 27: ...on Figure2 20 Removing a power supply Removing a PSR450 12D power supply 1 Wear an ESD wrist strap Make sure the strap makes good skin contact and is reliably grounded 2 Use a flat head screwdriver to...

Страница 28: ...onnects the power cord for a PSR250 12A1 power supply To connect the power cord for a power supply 1 Wear an ESD wrist strap Make sure the strap makes good skin contact and is reliably grounded 2 Plug...

Страница 29: ...orient the power cord connector and insert the connector into the power receptacle 2 Use a flat head screwdriver to fasten the screws on the connector to secure the connector to the power receptacle...

Страница 30: ...module 1 Wear an ESD wrist strap Make sure the strap makes good skin contact and is reliably grounded 2 Use a Phillips screwdriver to remove the screw on the filler panel in the target expansion slot...

Страница 31: ...Gently push the expansion module into the slot along the guide rails until the expansion module has good contact with the chassis See callout 1 in Figure2 26 b Use a Phillips screwdriver to fasten th...

Страница 32: ...stall a new expansion module install a filler panel in the slot to prevent dust and ensure good ventilation in the switch Verifying the installation Before powering on the switch verify the following...

Страница 33: ...e types of console cables can be used for connecting the switch to a configuration terminal As a best practice use a serial console cable for connection The switch is not provided with a serial consol...

Страница 34: ...ith a crimped RJ 45 connector at one end for connecting to the serial console port of the switch and a DB 9 female connector at the other end for connecting to the serial port on a configuration termi...

Страница 35: ...following installs the driver on the Windows system To install the driver on other operating systems see the installation guide in the driver compression package named by using the corresponding opera...

Страница 36: ...er installation wizard 5 Click Finish after the drive installation is completed Figure3 5 Finishing the driver installation 6 Connect the standard USB connector of the cable to the USB port of the con...

Страница 37: ...PC by using a micro USB console cable 1 Connect the standard USB connector to the USB port of the PC 2 Connect the micro USB connector to the micro USB console port of the switch 3 Click the following...

Страница 38: ...3 31 Figure3 7 Device Driver Installation Wizard 6 Click Continue Anyway Figure3 8 Software Installation 7 Click Finish...

Страница 39: ...site For more information about the terminal emulator programs see the user guides for these programs Configure the terminal parameters as follows Bits per second 9 600 Data bits 8 Parity None Stop bi...

Страница 40: ...rface and menu options differ with software versions For more information about Boot ROM menu options see the software matching release notes for the device After the startup process is completed you...

Страница 41: ...anageability An S5560X HI switch can set up an IRF fabric only with switches from the same switch series IRF fabric setup flowchart Figure4 1 IRF fabric setup flowchart Start Plan IRF fabric setup Ins...

Страница 42: ...l IRF ports Connect physical IRF ports on switches All switches except the master switch automatically reboot and the IRF fabric is established Planning IRF fabric setup This section describes issues...

Страница 43: ...does not cause the IRF fabric to split as in daisy chain topology Instead the IRF fabric changes to a daisy chain topology without interrupting network services You connect the IRF member switches thr...

Страница 44: ...5G 2 5G 1000BASE T autosensing Ethernet ports 10G 5G 2 5G 1000BASE T autosensing Ethernet ports SFP ports SFP28 ports QSFP ports Physical ports on interface modules and the front panel can be bound t...

Страница 45: ...tance IRF connection in an equipment room use a twisted pair SFP QSFP SFP28 cable For a long distance IRF connection use SFP QSFP SFP28 transceiver modules and optical fibers The following subsections...

Страница 46: ...4 39 Figure4 4 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...

Страница 47: ...4 40 Figure4 5 IRF fabric topology 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Страница 48: ...out configuring basic IRF settings see the virtual technologies configuration guide for the switch Connecting the physical IRF ports Use twisted pair SFP QSFP SFP28 cables or SFP QSFP SFP28 transceive...

Страница 49: ...t a reboot display irf configuration Display IRF fabric topology information display irf topology NOTE To avoid IP address collision and network problems configure a minimum of one multi active detect...

Страница 50: ...power supply see Installing and removing a power supply Fan tray failure WARNING If both fan trays fail during switch operation replace them within 2 minutes If one fan tray fails perform either of t...

Страница 51: ...does not have any issues and the terminal settings are correct 4 If the issue persists contact H3C Support Garbled display Symptom The display on the configuration terminal is garbled Solution To reso...

Страница 52: ...thernet port 4 13 10 100 1000BASE T autosensing Ethernet port 4 13 USB port 4 14 SFP port 4 14 SFP port 4 14 SFP28 port 4 18 QSFP port 4 19 10G 5G 2 5G 1000BASE T autosensing Ethernet ports 4 21 5G 2...

Страница 53: ...44 440 400 mm 1 73 17 32 15 75 in Weight 6 7 kg 14 77 lb 7 0 kg 15 43 lb 7 2 kg 15 87 lb 7 0 kg 15 43 lb Console port 1 micro USB console port 1 serial console port Only the micro USB console port is...

Страница 54: ...PSR250 12A PSR25 0 12A1 Single power supply 157 W Dual power supplies 160 W PSR450 12D Single power supply 157 W Dual power supplies 163 W PSR250 12A PSR25 0 12A1 Single power supply 172 W Dual power...

Страница 55: ...upply 1 PWR1 7 Power supply 2 PWR2 The S5560X 34C HI switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel You can install one or two power supplies f...

Страница 56: ...upply 1 PWR1 7 Power supply 2 PWR2 The S5560X 30F HI switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel You can install one or two power supplies f...

Страница 57: ...upply 1 PWR1 7 Power supply 2 PWR2 The S5560X 54F HI switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel You can install one or two power supplies f...

Страница 58: ...PWR1 7 Power supply 2 PWR2 The S5560X 58C HI switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel You can install one or two power supplies for the s...

Страница 59: ...ted Supported Supported Supported LSWM2SP8P Supported Supported Supported Supported LSWM4SP8PM Supported Supported Supported Supported LSPM6FWD Supported Supported Supported Supported LSPM6FWD8 Suppor...

Страница 60: ...switch supports the LSWM1FANSCE LSWM1FANSCBE FAN 40F 1 A and FAN 40B 1 A fan trays Table3 3 Fan trays available for the switch Fan tray model Item Specifications Reference LSWM1FANSCE from the power s...

Страница 61: ...es described in Table4 4 and 10 GE SFP transceiver modules and cables described in Table4 5 and Table4 6 Reference H3C LSWM4SP8PM Interface Card User Manual LSPM6FWD Description The card is a fourth g...

Страница 62: ...25GE SFP28 interface module Port type and quantity 2 25 Gbps SFP28 fiber ports Available transceiver modules and cables See SFP28 transceiver modules and cables described in Table4 8 and Table4 9 Ref...

Страница 63: ...distribution frame is preferably not adjacent for example If the device connects to one distribution frame connect port 1 on the device to port 1 on the distribution frame and port 2 on the device to...

Страница 64: ...the front panel You can connect this port to a PC or management station for loading and debugging software or remote management Table4 2 Management Ethernet port specifications Item Specification Conn...

Страница 65: ...sceiver modules and cables in Table4 4 in the SFP ports SFP port The switch provides fixed SFP ports on the front panel The LSWM2SP2PB LSWM2SP4PB LSWM4SP8PM and LSWM2SP8P interface cards also provide...

Страница 66: ...SM 1310 S 1310 LC Single mode 9 125 N A 10 km 6 21 miles SFP GE LH40 SM1310 1310 LC Single mode 9 125 N A 40 km 24 86 miles SFP GE LH40 SM1310 D 1310 LC Single mode 9 125 N A 40 km 24 86 miles SFP GE...

Страница 67: ...FP transceiver modules available for the SFP ports 10 GE SFP module Central wavelength nm Connector Fiber diameter m Modal bandwidth MHz km Max transmission distance SFP XG SX M M850 D 850 LC Multi mo...

Страница 68: ...X 1330 LC Single mode 9 125 N A 40 km 24 86 miles SFP XG LH40 SM1330 BIDI TX 1330 RX 1270 LC Single mode 9 125 N A 40 km 24 86 miles IMPORTANT The SFP XG LX SM1270 BIDI and SFP XG LX SM1330 BIDI trans...

Страница 69: ...ceiver modules and fibers To connect peer SFP28 ports over a short distance use SFP28 cables You can install SFP28 transceiver modules in Table4 8 and SFP28 cables in Table4 9 in the SFP28 ports Table...

Страница 70: ...the specifications of H3C transceiver modules and network cables see H3C Transceiver Modules User Guide QSFP port The switch and the LSWM2QP2P interface card provide QSFP ports You can install QSFP t...

Страница 71: ...150 m 492 12 ft QSFP 40G BI DI WDM850 Four lanes 850 880 910 940 LC Multi mode 50 125 2000 240 m 787 40 ft 4700 350 m 1148 29 ft Table4 11 QSFP cables available for the QSFP ports QSFP cable Max trans...

Страница 72: ...d must be the same in specifications including central wavelength and fiber type NOTE As a best practice use H3C transceiver modules and network cables for the switch The H3C transceiver modules and n...

Страница 73: ...MGT8P interface module provides 5G 2 5G 1000BASE T autosensing Ethernet ports Table4 14 describes the 5G 2 5G 1000BASE T autosensing Ethernet port specifications Table4 15 5G 2 5G 1000BASE T autosensi...

Страница 74: ...er supply is installed in the power supply slot MODE LED To show more information about the switch through the port LEDs the switch provides a MODE LED MODE to indicate the type of information that th...

Страница 75: ...e Steady green A link is present on the port and the port is operating at 1000 Mbps Flashing green The port is sending or receiving data at 1000 Mbps Off No link is present on the port Flashing yellow...

Страница 76: ...vely Table4 24 Expansion module status LED description LED mark Status Description SLOT1 SLOT2 Steady green The expansion module is present and is operating correctly Flashing yellow The switch does n...

Страница 77: ...odel for the switch Table5 1 describes fan trays available for the switch Table5 1 Cooling system of the switch Device model Fan tray model Airflow direction S5560X 30F HI S5560X 54F HI LSWM1FANSCE Fr...

Отзывы: