1-4
To do…
Use the command…
Remarks
Create an entry in the alarm table
rmon alarm
entry
-
number alarm
-
variable
sampling
-
interval
{
absolute
|
delta
}
rising-threshold
threshold
-
value1
event
-
entry1
falling-threshold
threshold
-
value2
event
-
entry2
[
owner
text
]
Optional
Create an entry in the private
alarm table
rmon prialarm entry-number prialarm-formula
prialarm-des sampling-interval
{
absolute
|
changeratio
|
delta
}
rising-threshold
threshold-value1 event-entry1
falling-threshold threshold-value2
event-entry2 entrytype
{
forever
|
cycle
cycle-period
} [
owner text
]
Optional
z
A new entry cannot be created if its parameters are identical with the corresponding parameters of
an existing entry Refer to
for the parameters to be compared for different entries.
z
The system limits the total number of each type of entries (Refer to
numbers). When the total number of an entry reaches the maximum number of entries that can be
created, the creation fails.
z
When you create an entry in the history table, if the specified
buckets number
argument exceeds
the history table size supported by the device, the entry will be created. However, the validated
value of the
buckets
number
argument corresponding to the entry is the history table size
supported by the device.
Table 1-1
Restrictions on the configuration of RMON
Entry
Parameters to be compared
Maximum number of
entries that can be
created
Event
Event description (
description
string
), event type (
log
,
trap
,
logtrap
or
none
) and community name
(
trap-community
or
log-trapcommunity
)
60
History
Sampling interval (
interval
sampling-interval
) 100
Statistics
Only one statistics entry can be created on an interface.
100
Alarm
Alarm variable (
alarm-variable
), sampling interval
(
sampling-interval
), sampling type (
absolute
or
delta
),
rising threshold (
threshold-value1
) and falling threshold
(
threshold-value2
)
60
Prialarm
Alarm variable formula (
alarm-variable
), sampling
interval (
sampling-interval
), sampling type (
absolute,
changeratio
or
delta
), rising threshold
(
threshold-value1
) and falling threshold
(
threshold-value2
)
50
Содержание S5500-SI Series
Страница 161: ...3 10 GigabitEthernet1 0 1 2 MANUAL...
Страница 220: ...1 7 Clearing ARP entries from the ARP table may cause communication failures...
Страница 250: ...3 3 SwitchB system view SwitchB interface vlan interface 1 SwitchB Vlan interface1 ip address dhcp alloc...
Страница 310: ...i Table of Contents 1 Dual Stack Configuration 1 1 Dual Stack Overview 1 1 Configuring Dual Stack 1 1...
Страница 331: ...1 7 1 1 ms 1 ms 1 ms 1 1 6 1 2 1 ms 1 ms 1 ms 1 1 4 1 3 1 ms 1 ms 1 ms 1 1 2 2 Trace complete...
Страница 493: ...2 8...
Страница 1111: ...1 10 Installing patches Installation completed and patches will continue to run after reboot...