17
Install the RPS1600-A by using the front mounting
brackets and a rack shelf
1.
Wear an ESD-preventive wrist strap and check the grounding
and stableness of the rack.
2.
Fix the rack shelf supplied with the rack horizontally at the
appropriate position of the rack.
3.
Unpack the supplied front mounting brackets and screws, and
attach the front mounting brackets to the front end of the
RPS1600-A with the screws, as shown in
.
4.
Place the RPS1600-A horizontally on the rack shelf, gently push
the unit into the rack along the rack shelf, and fix the mounting
brackets to the front square-holed posts of the rack with M6
screws and cage nuts (user supplied).
Installing the RPS1600-A on a workbench
If a 19-inch standard rack is not available, you can place the
RPS1600-A on a clean, stable workbench. Follow these steps to
install the RPS1600-A on the workbench:
1.
Cautiously turn the RPS1600-A upside down. Then, use a piece
of dry, soft cloth to remove any oil stain or dust from the dents on
the bottom of the chassis.
2.
Peel off the stickers on the supplied foot pads and paste the foot
pads into the dents on the chassis bottom.
3.
Turn over the RPS1600-A and place it on the workbench. Make
sure that the workbench is sturdy and well grounded.
Connecting the grounding cable
WARNING!
Correctly connecting the grounding cable is crucial to lightning
protection and EMI protection.