Interface Card and Interface Module Manual
H3C MSR 20/30/50 Series Routers
Chapter 3 Multifunctional Interface Modules
3-44
Table 3-25
Set the jumpers on the MIM-4BSE
Jumper settings & description
Default
S2
To use a 100-ohm matched resistance for data
transmission, place the jumper over pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
Interface
0
S1
To use a 100-ohm matched resistance for data
receiving, place the jumper over jump pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
S4
To use a 100-ohm matched resistance for data
transmission, place the jumper over pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
Interface
1
S3
To use a 100-ohm matched resistance for data
receiving, place the jumper over jump pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
S6
To use a 100-ohm matched resistance for data
transmission, place the jumper over pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
Interface
2
S5
To use a 100-ohm matched resistance for data
receiving, place the jumper over jump pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
S8
To use a 100-ohm matched resistance for data
transmission, place the jumper over pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
Interface
3
S7
To use a 100-ohm matched resistance for data
receiving, place the jumper over jump pins 1 and 2.
To do otherwise, place the jumper over jump pins 2
and 3.
See
Figure 3-51
.
The
jumpers are
placed over
jump pins 2
and 3,
meaning
100-ohm
matched
resistances
are not
used.