Interface Card and Interface Module Manual
H3C MSR 20/30/50 Series Routers
Chapter 3 Multifunctional Interface Modules
3-17
Caution:
AUX cable is optional. When ordering an MIM-8ASE or MIM-16ASE module, please
order an AUX cable also. By default, it is not provided. As for dumb terminal cables, you
can make them on site by reference to
Low-End and Mid-Range Series Routers Cable
Manual
.
3.5.5 Connecting the Interface Cable
Warning:
Before plugging or unplugging interface cables connected to an MIM-8ASE or
MIM-16ASE module, power off the Router. Online insertion or removal tends to
damage the module and even the device.
Caution:
Read the mark identifying a port before you connect a cable to it, making sure it is the
correct port. Wrong connection tends to damage interface modules and even the
Router.
Step 1: Check port type of the device to be connected and choose the correct cable;
Step 2: Connect one end of the cable to the Router and the other end to the peer
device;
z
AUX cable
Connect the DB-25/DB-9 connector to the network device, usually a modem;
z
Dumb terminal cable
Connect the RJ-45 connector (female) to a standard network cable and then to a dumb
terminal adapter;