Installation Manual
H3C S5100-SI/EI Series Ethernet Switches
Chapter 3 Installing the Switch
3-3
(1) Screw hole used to fix the mounting ear to the rack (Use one M6 screw)
Figure 3-2
Appearance of a rear mounting ear
When you install an H3C S5100 series switch into a 19-inch standard rack, you should
select front mounting ears with a proper length (L1 as shown in Figure 3-1) according to
the physical dimensions of the switch. For the selection of front and rear mounting ears,
see Table 3-3.
Table 3-3
Selection of mounting ear for the H3C S5100 series Ethernet Switches
Model
Physical dimensions
(H x W x D)
Configuration
type of front
mounting ear
Configuration
type of rear
mounting ear
S5100-8P-SI
S5100-8P-EI
43.6 × 230 × 200 mm
(1.7 x 9.1 x 7.9 in.)
Option
a
l
—
S5100-16P-SI
S5100-16P-EI
S5100-8P-PWR-EI
43.6 × 300 × 220 mm
(1.7 × 11.8 × 8.7 in.)
Option
a
l
—
S5100-24P-SI
S5100-24P-EI
S5100-48P-SI
S5100-48P-EI
43.6 × 440 × 260 mm
(1.7 × 17.3 × 10.2 in.)
Standard —
S5100-26C-EI
S5100-50C-EI
43.6 × 440 × 300 mm
(1.7 × 17.3 × 11.8 in.)
Standard —
S5100-16P-PWR-E
I
43.6 × 300 × 260 mm
(1.7 × 11.8 × 10.2 in.)
Op
t
ion
a
l
—
S5100-26C-PWR-E
I
S5100-50C-PWR-E
I
43.6 × 440 × 420 ×mm
(1.7 × 17.3 × 16.5 in.)
Standard Standard