Chapter 1 Product Overview
1-11
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs
(2): 1000Base-X SFP port status LED
(3): Console port
(4): 7-segment digitron display
(5): DC power LED
(6): Power LED
(7): Ethernet port mode switching LED
(8): Port status LED mode switch
Figure 1-14
Front panel of an S5100-24P-EI Ethernet switch
II. Rear panel
(1): AC power input
(2): DC power input
(3): Grounding terminal
Figure 1-15
Rear panel of an S5100-24P-EI Ethernet switch
III. Power supply system
An S5100-24P-EI switch provides AC power input and RPS DC input. The AC and DC
power inputs can be used at the same time, acting as backup for each other.
Alternatively, you can use either the AC power input alone or the DC power input alone.
Make sure you use an RPS module recommended by H3C as the DC power input.
z
AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz
Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z
DC input
Rated voltage range: -48 VDC to -60 VDC
Max voltage range: -36 VDC to -72 VDC