background image

Item

项目

 Specifications

规格

 

Output voltage 

输出电压

 

12 V 

Max output current 

最大输出电流

 

5.83 A 

Max output power 

最大输出功率

 70 

Dimensions (H × W × D) 

外形尺寸(高×宽×深)

 

41.1 × 101.6 × 177 mm (1.62 × 4 × 6.97 in) 

Weight 

重量

 

0.6kg (1.32 lb) 

Operating temperature 

工作温度

 

–10°C to 55°C (14°F to 131°F) 

Relative humidity 

相对湿度

 

5% to 95%, noncondensing 

5%

95%

,无冷凝

 

Storage temperature 

存储温度

 

-40°C to 70°C (–40°F to +158°F) 

 

 

 

 

 

Preparing for installation 

When installing and removing the power supply, wear an ESD wrist strap and make sure the wrist 

strap makes good skin contact.

在安装和拆卸电源模块时请注意佩戴防静电腕带,并确保防静电腕带与皮肤良好接触。

Before installing the power supply, make sure the operating voltage of the external power supply 

system is as required by the power supply, and the output voltage of the power supply is as 

required by the powered device.

在安装电源模块前,请确认外置供电系统的工作电压同电源模块所标电压、电源模块输出电压同受
电设备所需电压是否相符,避免对电源模块和受电设备造成损坏。

To avoid bodily injury, do not touch any bare wire or terminal.

不要接触露出的任何导线、端子部分,以免对人体造成伤害。

Never place the power supply in a wet area and prevent fluid from flowing into the power supply.

请不要将电源模块放置在潮湿的地方,也不要让液体进入电源模块。

To avoid damages, do not open the power supply. When an internal circuit or component of the 

power supply fails, contact H3C Support.

为了防止电源模块受损,请不要随意打开电源模块外壳,当电源模块内部线路或元器件出现故障时,

请移交维修人员进行检修。

Before installing or removing the power supply, make sure no power cord is connected to it.

安装和拆卸电源模块时,应确保电源模块上没有连接电源线。

Safety recommendations 

安全注意事项

1

Содержание CA-70A12

Страница 1: ...cy 1 1 Hot swappable You can remove one of power supplies in 1 1 redundancy while the device is operating Before removing a power supply first disconnect it from the external power supply system 1 1 C...

Страница 2: ...y stops supplying power Automatically restores power supplying after the output current decreases to an acceptable range Overtemperature protection The power supply stops supplying power Automatically...

Страница 3: ...d skin contact Before installing the power supply make sure the operating voltage of the external power supply system is as required by the power supply and the output voltage of the power supply is a...

Страница 4: ...orient it correctly and insert it again If the captive screw cannot be tightly fastened examine the installation of the power supply 2 Wear an ESD wrist strap and make sure it makes good skin contact...

Страница 5: ...flat head screwdriver into the holder on the filler panel and then pull the filler panel out of the slot along the guide rails gently See callout 2 in the following figure 1 1 2 2 1 2 Make sure the po...

Страница 6: ...on the power supply until the captive screws are disengaged from the device See callout 1 in the following figure Grasping the handle of the power supply with one hand pull it part way out Then suppor...

Страница 7: ...1 1 2 Copyright 2020 New H3C Technologies Co Ltd The information in this document is subject to change without notice Copyright 2020 H3C www h3c com...

Отзывы: