7
<Sysname>tftp 192.168.1.1 put flash:/uis-cmw710-boot-1.00.10.bin
Press CTRL+C to abort.
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
100 5572k 0 0 100 5572k 0 832k 0:00:06 0:00:06 --:--:-- 828k
<Sysname>
4.
In the user view on the CLI of the switch module, run the
tftp put
command to back up profile
startup.cfg
on the TFTP file server:
<Sysname>tftp 192.168.1.1 put startup.cfg
Press CTRL+C to abort.
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
100 6549 0 0 100 6549 0 270k --:--:-- --:--:-- --:--:-- 319k
<Sysname>
Common operations
Logging in to the Web UI of the OM module
Prerequisites
•
The blade enclosure has been energized.
•
You have obtained the login data of the OM module.
Procedure
1.
As shown in
, connect the Ethernet interface of the PC to the MGMT interfaces of the
active or standby OM module through the LAN. Ensure that the IP addresses of the PC and OM
module are accessible on L3.
Figure 18 Setting up the hardware environment
PC
LAN
Enclosure