  Main  body  (wrist  watch):  The  main  body  is  central  processing  part 
composed  of  LCD  display,  start-stop  button,  measurement  button, 
communications terminals and a built-in communication module. 

 

 

 

Ⓐ  communication terminal: IN-OUT serial communication port 

Ⓑ  LCD display : LCD screen that displays various information. 

Ⓒ  "S" (Start / Stop) Button: power ON / OFF 

Ⓓ  "M" (Measurement) Button: Start measurement. 

 

Sensor  cable:  Connect  the  main  body  and  the  sensing  part  that  makes  it 
possible to transfer the information. 

 

Gloves 

 

Sensor mounts : a sensor fixation part 

 

Wrist strap 

 

Sensing  part  :  optical  parts  which  measures  PPG(Photo  plethysmography) 
signal. It measures the amount of the reflected light compared to the acting 
light at the finger 

 
 

Содержание HRM-1000

Страница 1: ...Heart Rate Monitor HRM 1000 User s Manual H3 System Co Ltd ...

Страница 2: ... based on the optics The amount of the reflected light compared to the acting light is measured at the sensing part The change of the light reflectance is thereafter analyzed to calculate heart rate at the main body wrist watch Calculated pulses are displayed on the LCD screen of wrist watch and can be wirelessly transmitted to other devices PC or smart phone This device uses a rechargeable batter...

Страница 3: ...splay LCD screen that displays various information Ⓒ S Start Stop Button power ON OFF Ⓓ M Measurement Button Start measurement Sensor cable Connect the main body and the sensing part that makes it possible to transfer the information Gloves Sensor mounts a sensor fixation part Wrist strap Sensing part optical parts which measures PPG Photo plethysmography signal It measures the amount of the refle...

Страница 4: ...ist 2 Press the S start button LCD is ON and displays the device ID and the current settings The status of the monitor is marked as dot to the left of the display The modes are Set Mode and Com By default should appear at Set and Com at the same time 2 Heart rate measurement 1 In order to start the heart rate measurement press M Measure On button Measuring Notes The initial 10 seconds are needed t...

Страница 5: ...isplay After you wear off the gloves please be kept charged by plugging in the adapter 2 Pressing S stop button If the monitor displays BUSY you should not do any operation and let it terminate automatically 4 How to store and maintenance 1 Storage environment Temperature 10 55 humidity is kept at less than 95 2 The following points should be taken when storing not exposed to corrosive gases shoul...

Страница 6: ...protection to protect against electrical shock The internal power type equipment BF type mounting 2 Electrical Rating DC 3 7V Lithium polymer battery V Matters 1 The product name model name model heart rate monitor HRM 1000 2 the manufacturer s name and address Company Name H3 System Co Ltd Address 3rd floor Daedeok Bldg 397 27 Doryong dong Yuseong gu Daejeon city Korea republic of Phone 81 42 862...

Страница 7: ...measure and display heart rate during exercise 7 Other necessary matters The type and degree of protection to protect against electrical shock The internal power type equipment BF type mounting Electrical Rating DC 3 7V Lithium polymer battery 8 This device is for medical equipment in Korea The above information is listed on the back of the device packaging and attachments ...

Страница 8: ...ncy energy If not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try and c...

Отзывы: