background image

I. General Description 

 

This  device  is  to  measure  heart  rate  and  being  composed  of  main  body  (wrist 

watch),  sensing  part,  gloves,  a  charging  adapter  and  a  software  (Optional).  Main 
body and the sensing part is connected to each other and can be mounted on the 
glove. 

The  measurement  principle  is  based  on  the  optics.  The  amount  of  the  reflected 

light compared to the acting light is measured at the sensing part. The change of the 
light reflectance is thereafter analyzed to calculate heart rate at the main body(wrist 
watch). 

Calculated  pulses  are  displayed  on  the  LCD  screen  of  wrist  watch,  and  can  be 

wirelessly transmitted to other devices, PC or smart phone. 

This device uses a rechargeable battery and can be charged through DC adapter. 

   

II. Component Description 

 

1. Heart rate monitor 

 

Содержание HRM-1000

Страница 1: ...Heart Rate Monitor HRM 1000 User s Manual H3 System Co Ltd ...

Страница 2: ... based on the optics The amount of the reflected light compared to the acting light is measured at the sensing part The change of the light reflectance is thereafter analyzed to calculate heart rate at the main body wrist watch Calculated pulses are displayed on the LCD screen of wrist watch and can be wirelessly transmitted to other devices PC or smart phone This device uses a rechargeable batter...

Страница 3: ...splay LCD screen that displays various information Ⓒ S Start Stop Button power ON OFF Ⓓ M Measurement Button Start measurement Sensor cable Connect the main body and the sensing part that makes it possible to transfer the information Gloves Sensor mounts a sensor fixation part Wrist strap Sensing part optical parts which measures PPG Photo plethysmography signal It measures the amount of the refle...

Страница 4: ...ist 2 Press the S start button LCD is ON and displays the device ID and the current settings The status of the monitor is marked as dot to the left of the display The modes are Set Mode and Com By default should appear at Set and Com at the same time 2 Heart rate measurement 1 In order to start the heart rate measurement press M Measure On button Measuring Notes The initial 10 seconds are needed t...

Страница 5: ...isplay After you wear off the gloves please be kept charged by plugging in the adapter 2 Pressing S stop button If the monitor displays BUSY you should not do any operation and let it terminate automatically 4 How to store and maintenance 1 Storage environment Temperature 10 55 humidity is kept at less than 95 2 The following points should be taken when storing not exposed to corrosive gases shoul...

Страница 6: ...protection to protect against electrical shock The internal power type equipment BF type mounting 2 Electrical Rating DC 3 7V Lithium polymer battery V Matters 1 The product name model name model heart rate monitor HRM 1000 2 the manufacturer s name and address Company Name H3 System Co Ltd Address 3rd floor Daedeok Bldg 397 27 Doryong dong Yuseong gu Daejeon city Korea republic of Phone 81 42 862...

Страница 7: ...measure and display heart rate during exercise 7 Other necessary matters The type and degree of protection to protect against electrical shock The internal power type equipment BF type mounting Electrical Rating DC 3 7V Lithium polymer battery 8 This device is for medical equipment in Korea The above information is listed on the back of the device packaging and attachments ...

Страница 8: ...ncy energy If not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try and c...