The Activated Carbon Pod helps to reduce any 
noticeable taste or residual gases. Replace the 
Activated Carbon Pod every 30 to 60 days, or 
whenever there is any noticeable taste or odor.  
 

To replace the Pod

, press the middle tabs on 

each side of the nozzle and TILT it out of the 
slots. (See illustration.) 

Use force if necessary.

  

 Press the tabs carefully to prevent breaking the Glass Insert. (Should 
the Glass Insert break, replacements are available. However it is 
perfectly acceptable to continue using the distiller without the Glass 
Insert as the Nozzle is made from food-grade, safe material.)

 

 

It may be helpful to use small flat head screwdriver to push the Nozzle 
tabs in to release them from the slots. If using a screwdriver, be careful 
not to enlarge or damage the slots. 

 

It is normally not necessary to clean the Glass Insert until changing the 
Activated Carbon Pod. When necessary to remove it, take care to 
prevent breakage. Gently press top of Nozzle and insert a small flat-
tipped screw driver under the release tab to slide the Glass Insert out. 
 

     

     

 

 
TIPS 

As mentioned previously,

 Run your system at night

 - Prepare the unit 

at any convenient time during the day. But wait until before retiring 
each night to turn it on. That way, any noticeable noise or heat from the 
process will be minimized. More importantly, the unit will have ample 
time to cool down by morning which will make it quicker, easier and 
safer to clean and prepare for the next cycle. Plus you’ll have a fresh 
and full 4 Litres first thing in the morning to enjoy all day. 

- 14 - 

Содержание 300F

Страница 1: ...Distillation System You ll soon be making the PUREST water you can drink PLEASE READ THIS INSTRUCTION MANUAL for a quick easy and enjoyable water making experience DO NOT DISCARD SHIPPING BOX OR STYR...

Страница 2: ...lies See above Glass Carafe Inside unit See Carafe Instructions before removing Nozzle with Glass Insert Shipped inside Glass Carafe Main Power Cord Inside Styrofoam packaging Activated Carbon Pods 6...

Страница 3: ...rd to the wall outlet LAST When disconnecting the Fan and Main Power Cords always unplug the Main Power Cord from the wall outlet FIRST Push plugs firmly all the way into the sockets to avoid a poor c...

Страница 4: ...make your water distillation experience even easier and more enjoyable SAFETY INSTRUCTIONS Read Before Assembling Carafe CAUTION Always handle the Glass Carafe with care to avoid breakage and possible...

Страница 5: ...f the water distiller Head Assembly and remove the package inside Carefully pull out the glass Carafe 2 Open the package and locate all parts as specified below Handle Handle Cover Lid Nozzle with Gla...

Страница 6: ...e the same for both straps 5 Align right hand side of the screw slots to the black reference line on the Carafe label 6 Fit the handle over the two screw slots Align the Handle with the slots and the...

Страница 7: ...ed to the black reference line When done correctly the Handle will also be aligned with the spout on the opposite end If necessary loosen the screws and re adjust 11 Lift the Carafe by the handle a fe...

Страница 8: ...dle and the other hand supporting the bottom of the Carafe An easy way to pour from a full Carafe is to allow it to rest on the countertop thereby supporting the weight while tilting it to fill a drin...

Страница 9: ...ING INSTRUCTIONS Follow these simple steps to ensure that you maintain a continuous supply of drinking water It only takes a couple minutes to prepare the unit to begin the distillation process Do not...

Страница 10: ...er Outlet being careful not to break the Glass Insert Note See Maintenance section for additional Activated Carbon Pod and Glass Insert instructions 6 Line up the Nozzle with the spout of the glass Ca...

Страница 11: ...to make brand new water It has to evaporate and then condense back into liquid again in the form of rain or distilled water Because distilled water must be converted to steam vapor and then condensed...

Страница 12: ...ater Cleaning in this manner will produce a slight polishing effect on the interior of the boiling tank to reduce any surface coarseness A couple minutes is all it takes to clean and prepare the unit...

Страница 13: ...ext cycle 7 Place unit on the counter top and dry the exterior with a soft cloth after each cleaning and filling to prevent water or rust spots Also insure that the Fan Plug and both outlet sockets on...

Страница 14: ...n to release them from the slots If using a screwdriver be careful not to enlarge or damage the slots It is normally not necessary to clean the Glass Insert until changing the Activated Carbon Pod Whe...

Страница 15: ...ce to push the fan cord plug into the fan cord socket Main power cord not plugged firmly into the household outlet or unit No power to the household electrical outlet Power Reset button not pressed No...

Страница 16: ...Hz Consumption 580W Total The H2oLabs Countertop Water Distillation System will provide your household with THE PUREST WATER POSSIBLE and it s made fresh every day to taste great To order Activated Ca...

Отзывы: