15
TROUBLESHOOTING
TROUBLESHOOTING
LOW WATER PRESSURE FROM DISPENSING FAUCET
POSSIBLE
CAUSE / SOLUTION
Carbon Post Filter is clogged.
Replace Post Filter.
The Faucet is out of
adjustment or faulty.
Repair or replace Faucet.
TASTES AND ODORS IN PRODUCT WATER
POSSIBLE
CAUSE / SOLUTION
Carbon Post Filter is
exhausted.
Replace Filter.
Dissolved gases in feed water.
Pre-treat feed water to remove gases.
FAUCET LEAKS OR DRIPS
POSSIBLE
CAUSE / SOLUTION
Water leaks from faucet spout.
Adjust faucet by turning the tee bar located under the handle
to provide a small amount of free play in the handle when
shut off. Should this not work, repair or replace the faucet.
Leaks from beneath the handle.
Repair or replace the faucet.
NO WATER
POSSIBLE
CAUSE / SOLUTION
Water is shut off at stop valve
Open main stop valve. (See diagram on page 13)
POSSIBLE
CAUSE / SOLUTION
Feed water valve is plugged
or closed.
Open valve or unclog.
Sediment/Carbon prefilter or
Carbon Post Filter is clogged.
Replace Filters.
Low incoming water pressure.
Incoming water pressure must be above 40 PSI. Install
a Booster Pump or Permeate Pump.
NOT ENOUGH WATER