4.  WATER FILTRATION SYSTEM PLACEMENT AND MOUNTING

1.

The system does not need to be mounted on the wall of the cabinet and simply sits on

the floor of the cabinet.

IMPORTANT!!

 

Be very careful not to kink any of the tubing on the water filtration system.  

If tubing is kinked the tubing can rupture and leak.

10

5. INSTALLATION OF FLOWLOK LEAK CONTROL VALVE

FLOWLOK is a specially designed shut off valve that turns off your water when a leak is 

detected.  The FLOWLOK valve uses  a compressed textile disc which expands upon water 

contact and pushes the valve lever up to the closed position to stop all water flow into the 

drinking water system.  

NOTE:  The FLOWLOK will not shut off any water leak originating from the stop valve or any other connection 

which feeds water to it.  FLOWLOK is designed to shut off water which is going into the drinking water system

(Please note that you can order replacement textile discs through you local dealer in case a disc accidentally 

becomes wet and expands.)

WARNING!!! 

 The FLOWLOK valve MUST be installed to prevent any water leaks occurring 

from the drinking water system. Failure to install the FLOWLOK valve will automatically void 

the product warranty.

1. 

Locate compressed textile disc and set aside. 

2.

Place FLOWLOK 2 inches from side wall of

cabinet and 4 - 6 inches from the drinking

water systems inlet side.

3. 

Affix the FLOWLOK with screws to the cabinet 

base (floor) with screws.

4. 

Lift FLOWLOK Lever to off position.

5. 

Once final connection is made, remove lever

pusher and insert textile disc with the

pronounced part towards the bottom and

reinsert lever pusher. Lower on/off lever to

allow water to flow thru the system. 

UNIT PLACEMENT & FLOWLOK INSTALLATION

WHITE TUBE

(to system INLET)

WHITE TUBE 

(from FEEDWATER ADAPTOR)

ON  OFF

ON/OFF 

LEVER

COMPRESSED

TEXTILE DISC

SCREWS

LEVER

PUSHER

(

U.S.A patent pending

)

Содержание Guard U1000

Страница 1: ...INSTALLATION INSTRUCTION MANUAL UNDER COUNTER D R I N K I N G W A T E R S Y S T E M 1 2 STAGE SYSTEMS...

Страница 2: ...TECTION ELECTRICAL WARNING FRAGILE LEGEND WARNING READ ENTIRE MANUAL FAILURETO FOLLOW ALL GUIDES AND RULES COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE Checkwithyourstateand orlocalpublicworksdepart...

Страница 3: ...s Phillips screwdriver Flashlight or droplight Teflon tape Protective eye wear i e goggles 1 Filtration system 1Stageand2Stageavailable 2 Faucet with mounting hardware PARTS already pre installed in s...

Страница 4: ...stem is designed to operate at a water pressure in the range of 40 to 80 PSI 2 95 kg cm2 to 5 6 kg cm2 At pressures lower than this the quantity as well as quality will be reduced At higher pressure s...

Страница 5: ...PTER COLD WATER METAL BALL VALVE FLOWLOK PLUMBING SCHEMATIC FOR 1 2 STAGE UNDER COUNTER FILTER SYSTEMS U2000 2 Stage Under the Counter Model shown CAUTION DO NOT USE WITH WATER THAT IS MICROBIOLOGICAL...

Страница 6: ...ocal distributor or experienced plumber be consulted for techniques installation or other assistance The system s manufacturer accepts no responsibility for sink top damage resulting from system insta...

Страница 7: ...tain surfaces very quickly HELPFUL HINT If you notice any rust spots from dropped shavings you should be able to get rid of them by scrubbing them with a cleaning chemical 8 Coverthedrilledholewithyou...

Страница 8: ...r Connect Metal Ball Valve to the feedwater connector Insert washer into bottom of the feedwater connector Insert washer into bottom of the feedwater connector Filter Tubing Blue Tube Filter Tubing Bl...

Страница 9: ...shut off valves have a built in smooth or corrugated riser going up to the faucet Refer to DIAGRAM E for help with this type of valve Secure an adjustable wrench to the fitting on the cold water side...

Страница 10: ...oing into the drinking water system Please note that you can order replacement textile discs through you local dealer in case a disc accidentally becomes wet and expands WARNING The FLOWLOK valve MUST...

Страница 11: ...nylon ferrule NOTE It is not necessary to have a 1 4 nylon insert in this line as it would restrict the flow through the faucet 2 Push the blue line all the way into the faucet stem and tighten the ch...

Страница 12: ...g can cause failure 2 INSPECT AND TEST Push and pull the tubing toward and away from the fitting to ensure that it has been installed properly Test and inspect the installation for any leaks 3 TUBE RE...

Страница 13: ...ust be in the horizontal position 2 Immediately check entire water filtration system for leaks If you notice any leaks turn off cold water supply and fix the leak 8 FLUSHING THE WATER FILTRATION SYSTE...

Страница 14: ...LUG BATTERY Unplug battery connector STEP 7 UNSCREW REPLACE Unscrew battery case and replace batery STEP 8 SCREW PLUG Screw back battery case and plug battery connector STEP 9 UNSCREW HOUSING Unscrew...

Страница 15: ...om faucet spout Adjust faucet by turning the tee bar located under the handle to provide a small amount of free play in the handle when shut off Should this not work repair or replace the faucet Leaks...

Страница 16: ...16 DATE CARTRIDGE 1 CARTRIDGE 2 CARTRIDGE 3 CARTRIDGE 4 SERVICE RECORD SERVICE RECORDS...

Страница 17: ...inking Water System is not subject to abuse misuse alteration neglect freezing misapplication neglect alteration water pressure spikes accident or negligence and provided further that the Drinking Wat...

Страница 18: ...18 NOTES NOTES...

Страница 19: ...YSTEMS U2000 SERIES 2 STAGE UNDER COUNTER DRINKINGWATER SYSTEMS U3000 MODELS U1000 MCB MICROBAN CARBON BLOCK HDG MCB U1000 CER MICROCERAMIC HDG CER U1000 UF ULTRAFILTRATION HDG UF U4000 MODELS U2000 G...

Страница 20: ...DISTRIBUTED BY...

Отзывы: