background image

FlowVis® - INSTRUCTION MANUAL

Page 4

The Virginia Graeme Baker Pool & Spa Act requires 
that all public swimming pools & spas that have a 
single main drain or multiple drains that are 3 feet 
or less (center to center) from each other, be fi tted 
with a backup anti-entrapment system. Such systems 
include, but are not 
limited to, SVRS and 
Automatic Pump 
Shut Off  systems. 

Special consideration must be made when installing 
a FlowVis® to such applications. Several of these 
systems do not allow the use of Check Valves. It is the 
responsibility of the installer to make sure that the 
requirements of the specifi c backup system in use are 
maintained.

An optional non-sealing fl apper is available for 
these installations.

7.0 

MODELS

FlowVis® is available in two diff erent models:

Model #

Description

FVJ-R

Retrofi t kit for existing Jandy® 7305 Check Valve

FV-C

Fully-assembled FlowVis®

FV-C-S

Fully assembled FlowVis® with safety fl apper

6.0 

WARNINGS & SAFETY  

Check Valves should always be installed in accordance with the original manufacturer’s 
instructions. When purchased as a complete Check Valve & Flow Meter combination, a 
copy of these instructions will be included with the FlowVis® packaging. If a FlowVis® 
retrofi t kit has been purchased, it is the installer’s responsibility to ensure that the Check 
Valve has been installed correctly and does not violate any local or federal codes relating 
to Check Valves.

5.0 

APPLICATIONS

FlowVis® is specifi cally designed for use in fresh water applications (i.e., swimming 
pools, spas, fountains, water features, etc). It is not suitable for applications that are 
contaminated with debris of such a size that it would prevent the check valve fl apper 
from fully seating against the valve body.

Содержание FLOWVIS

Страница 1: ...FlowVis H2flow Controls Inc 3545 Silica Road Unit F Sylvania OH 43560 USA Tel 888 635 0296 Fax 419 517 9900 E mail sales h2flow net www h2flow net Flow Meter Instruction Manual H2flow Controls Inc ...

Страница 2: ...ave virtually no installation limitations However some low grade chlorinators and other chemical feeder systems may not prohibit chemical introduction into the system when the pool s filtration system is shut down In these circumstances chlorine gas will develop and will normally rise to the highest point possible in the filtration system FlowVis should never be installed at this location as damage ...

Страница 3: ...ndicator arm O ring and calibrated scale Installation simply requires the removal of the eight screws securing the existing lid installing the new O ring and securing the FlowVis with the original eight screws 2 0 CONCEPT As flow increases the check valve flapper extends towards its fully open position The angular position of the flapper is determined by the flow through the valve body A calibrate...

Страница 4: ...t models Model Description FVJ R Retrofit kit for existing Jandy 7305 Check Valve FV C Fully assembled FlowVis FV C S Fully assembled FlowVis with safety flapper 6 0 WARNINGS SAFETY Check Valves should always be installed in accordance with the original manufacturer s instructions When purchased as a complete Check Valve Flow Meter combination a copy of these instructions will be included with the...

Страница 5: ...low meters FlowVis is not effected by flow stream disturbances caused by its proximity to pumps elbows tees valves etc FlowVis does not require specific straight pipe lengths before or after its point of installation and can be installed close to or even adjacent to other plumbing fittings FlowVis can be installed either horizontally or vertically NOTE When selecting a physical location to install...

Страница 6: ... the vertical leading edge of the red arm NOTE Slowly move your head in this direction to the point where the leading edge of the indicating arm is not visible 10 0 MAINTENANCE Although FlowVis is designed to be maintenance free periodic checks should be made to the following Item Check for Remedy O ring seal Check for leaks Replace O ring Valve Body Check for cracks or damage Replace entire FlowV...

Страница 7: ...7 psi at 20 gpm 2 23 at 110 gpm Head Loss when installed to 2 5 pipe FV C 0 71 psi at 21 3 gpm 2 37 psi at 112 6 gpm Accuracy when installed to 2 5 straight pipe FV C Range 20 110 gpm average accuracy 2 28 Accuracy when installed to 2 5 in between elbows FV C Range 20 110 gpm average accuracy 1 42 Minimum operating ambient temperature All 32ºF 0ºC Maximum operating ambient temperature All 140ºF 60...

Страница 8: ...chlorination system as described on page 2 of this manual 5 Charges Under cover of this warranty H2flow Controls Inc will pay the carriage and insurance charges for the shipment of defective product back to H2flow Controls Inc and for its return to the client s original site of dispatch except when a H2flow Controls Inc s product return policy has not been followed b product failure is caused by a...

Отзывы: