3. INSTALLATION
3-
3.7. CONNECT POWER SOURCE WIRES
1.
Before connecting the power wires make sure the voltage between the machine
and your factory power source is the same.
2.
Connect the power wires to the L1, L2, L3 connection points inside the electrical
control box.
3.
The machine must be properly grounded to prevent possible injury from electrical
shock.
4.
For wiring to different voltage, be sure to rewire upper cutterhead motor, lower
cutterhead motor, infeed table elevation motor, spike conveyor motor and
transformer to the correct voltage. Also, be sure to replace fuse s to protect the
electrical components. See the current consumption as instructed on model
variation chart or contact our distributor.
5.
All electrical connections should be performed by qualified electrical personnel.
Grounding should be based on the local regulations.