3. INSTALLATION
3-
3.6. POWER SUPPLY REQUIREMENT
Insufficient voltage from factory power source may affect the power output of the motor
and the function of the controller.
It is important to connect this machine to the correct voltage in the factory power
source. Use only an independent power source.
Table for power supplies requirement:
Model
Kw
Voltage
Current
Breaker capacity
Wire size
GT-400BRD-CE
15Kw
220V, 50/60Hz
68 A
100 A
22 mm²
GT-400BRD-CE
15Kw
400V, 50Hz
36 A
75 A
14 mm²
OPTION
20.5Kw 220V, 50/60Hz
93 A
125 A
22 mm²
OPTION
20.5Kw
400V, 50Hz
50 A
100 A
14 mm²
GT-610BRD-CE 20.5Kw
400V, 50Hz
50 A
100 A
14 mm²
OPTION
28Kw
400V, 50Hz
68 A
125 A
14 mm²