6.2 for deVIces WITh fIrmWare V1.10
(deVIces afTer end of 2016)
Starting from this version adjustment
options in 0,1°C increments are possible
noTe:
Every menu item consists of two displays that appear after each other:
the first display shows the name of the menu, the second display will indicate
its value.
When pressing
seT
the device will switch to setting mode. Following menu
items will appear in the display:
menu sTep n1 – sWITch on
On
23.4
Identified by the symbol shown in first position, the
on
. Here you can select
the temperature at which an external device should be switched ON. The value
can be selected with the buttons
56
in 0,1°C increments. The selection is
confirmed by pressing
seT
and the display will switch to the next step.
Settings range: -55,0°C…+125,0°C
menu sTep n2 – sWITch off
Off
25.1
Identified by the
off
. Here you can select the temperature at which an ex-
ternal device should be switched OFF. The value can be selected with the
buttons
56
in 0,1°C increments. The selection is confirmed by pressing
seT
and the display will switch to the next step.
Settings range: -55,0°C…+125,0°C