Cold current/Background 

current)

Cold current setting in PULSE mode.

Downslope 

Current lowering ramp setting.

Post gas

Post-Gas time setting. This time corresponds to the duration 

of gas protection after the arc has been extinguished. It 

protects the weld pool and the electrode against oxidisation 

when the metal is cooling down.

HMI OPERATION AND DESCRIPTION OF ITS BUTTONS

• 

On / Off button

This key is used to activate or deactivate the machine from sleep mode. The sleep mode cannot be activated while the machine is welding.

 

Welding process selection button

This key is used to select the welding process. Each successive press toggles between the following welding processes: TIG HF / TIG LIFT / MMA. 

The LED indicates the selected process.

Note: the process selected by default at machine startup corresponds to the last process used before the last sleep or shutdown. 

• 

Trigger mode selection button

Use this button to configure how the trigger is used. Each successive press toggles between the following modes: 2T / 4T / 4T LOG. The LED indicates 

the selected mode.

Note: the trigger mode selected by default at machine startup corresponds to the last trigger mde used before the last sleep or shutdown. For more 

information, refer to the section "Compatible Torches and Trigger Behavior".

 

Selecting sub-processes button

This key is used to select the "Sub-process". Each successive press toggles between the following sub-processes: PULSE / SPOT (only in TIG mode) 

/ MMA PULSE (only in MMA mode). The LED indicates the selected process.

Note:

 PULSE mode is only accessible in DC TIG mode.

SPOT mode is not accessible in 4T & 4T Log trigger configuration and in MMA PULSE welding mode.

Note: the sub-process selected by default at machine startup corresponds to the last sub-process used before the last sleep or shutdown.  

 

AC or DC current selection button

This key is used to select the current type when the TIG process is activated. Each successive press toggles between the following modes : DC / AC 

/ AC - Easy. The LED indicates the selected process.

Note: the process selected by default at machine startup corresponds to the last process used before the last sleep or shutdown.

• 

Main incremental encoder

As default, the incremental encoder allows the adjustment of the welding current.. It is also used to set the values of other parameters which are then 

selected via the associated keys. Once the parameter setting has been completed, it is possible to press the key of the parameter that has just been 

set again so that the incremental encoder is again linked to the current setting. It is also possible to press another key related to another parameter to 

adjust it. The buttons concerned are the BP1 to BP5 and the adjustment BP in AC. If no action is performed on the HMI for 2 seconds, the incremental 

encoder is again linked to the welding current setting.

 

Pre-Gas  button

The Pre-Gas adjustment is done by pressing and releasing the Pre-Gas button and then activating the main incremental encoder. Pre-Gas value in

-

creases when the incremental encoder is operated clockwise and decreases when it is operated anti-clockwise. Once the setting has been made, it 

is possible to press and release the Pre-Gas button again to re-link the main incremental encoder to the current setting or to wait for 2 seconds. The 

setting step is 0.1 sec. The minimum value is 0 sec. and the maximum value is 60 sec.

  

Post-Gas button

The Post-Gas adjustment is done by pressing and releasing the Post-Gas button and then activating the main incremental encoder. Post-Gas value 

increases when the incremental encoder is operated clockwise and decreases when it is operated anti-clockwise. Once the setting has been made, it 

is possible to press and release the Post-Gas button again to re-link the main incremental encoder to the current setting or to wait for 2 seconds. The 

setting step is 0.1 sec. The minimum value is 0 sec. and the maximum value is 60 sec.

 

Up Slop or current control button 

The curremt ramp-up setting is done by pressing and releasing the current ramp-up button and then by activating the main incremental encoder. Cur-

rent ramp-up value increases when the incremental encoder is operated clockwise and decreases when it is operated anti-clockwise. Once the setting 

has been made, it is possible to press and release the current ramp-up button again to re-link the main incremental encoder to the current setting or 

to wait for 2 seconds. The setting step is 0.1 sec. The minimum value is 0 sec. and the maximum value is 25 sec.

 

Incremental encoder for fading or "Down Slop" adjustment  

The "Down-Slop" incremental encoder is used to set the value of the current fading (clockwise increase and counterclockwise decrease). The value is 

visible on the 7-segment display and remains displayed for 2 seconds if an action on the incremental encoder is performed. 

 

Cold current control button

When one of the 2 processes "HF TIG" or "LIFT TIG" is selected, the cold current setting button is used to adjust the value of the cold current (only 

in 4T Log trigger configuration). The value can be adjusted between 20% and 99% of the welding current. The incremental step is 1%. This value is 

also adjustable in the "TIG DC Pulse" and "MMA Pulse" processes. 

22

EN

Translation of the original instructions

PROTIG 201 AC/DC - 201L AC/DC

Содержание PROTIG 201 AC/DC

Страница 1: ...4 09 2020 FR 2 15 97 104 EN 16 28 97 104 PROTIG 201 AC DC 201L AC DC DE 29 41 97 104 ES 42 54 97 104 RU 55 68 97 104 www gys fr Find more languages of user manuals on our website IT 83 96 97 104 NL 69...

Страница 2: ...eyes during cleaning operations Contact lenses are prohibited during use It may be necessary to install fireproof welding curtains to protect the area against arc rays weld spatter and sparks Inform t...

Страница 3: ...e that the cable cross section is adequate with the usage extensions and welding cables Always wear dry clothes which are in good condition in order to be isolated from the welding circuit Wear insula...

Страница 4: ...tween the conduct and the casing of the welding current source b Maintenance of the arc welding equipment The arc welding machine should be subject to a routine maintenance check according to the reco...

Страница 5: ...Flexible Voltage feature and needs to be powered by an earthed electrical installation between 110V and 240V 50 60Hz For intensive use at 110 V replace the original plug with a 32 A plug protected by...

Страница 6: ...on the control board red box on diagram below n 2 4 Turn the switch located on this control card ON The red LED switches off 5 The VRD function is activated 6 Screw the power source cover back on 7 O...

Страница 7: ...ot modes AC DC Choose between TIG DC TIG AC and TIG AC Easy AC Select the parameter to be adjusted between Frequency and Balance A V display selection By default the welding current is displayed on th...

Страница 8: ...e current setting It is also possible to press another key related to another parameter to adjust it The buttons concerned are the BP1 to BP5 and the adjustment BP in AC If no action is performed on t...

Страница 9: ...setting by pressing the A V button ISO Set the welding end current it is set as a percentage of the welding current setpoint It can be adjusted between 10 and 200 Validate the entered setting by press...

Страница 10: ...rch trigger the arc starts without contact using High Frequency impulsions 3 The initial welding current flows the weld will be continues according to the welding cycle 1 Position the torch nozzle and...

Страница 11: ...37 3 2 mm 60 A 180 A 43 4 0 mm 75 A 200 A 50 With this mode the frequency value is related to the welding current value as follows Current A Frequency Hz 10 40 117 41 90 100 91 140 79 141 170 70 171 2...

Страница 12: ...ay With the incremental encoder select a job number Only numbers associated with existing jobs can be displayed Press successively 3 times on the JOB button The selected job is now deleted and the pow...

Страница 13: ...s from I welding to I cold The secondary button is released the current switches from I cold to I welding T3 A long press on the main button 0 5 sec the cycle switches to DownSlope and stops in the I_...

Страница 14: ...of the current from the minimum current to 100 of the set intensity In TIG the welding machine only operates in 2T mode The upslope and downslope are not automatically managed by the current source a...

Страница 15: ...tion cable pedal connector Kabel Anschluss f r Fernsteuerung Cable conector pedal Kabel aansluiting pedaal Fasciocavo connettore pedale 71513 5 lectrovanne Solenoid valve Magnetventil Electrov lvula M...

Страница 16: ...Anschluss Conexi n gas Gasaansluiting Connessione gas 55090 19 Connecteur torche faisceau Torch connection Connection cable Brenner Anschluss Zwischenschlauchpaket Conector antorcha cable de uni n Aan...

Страница 17: ...E SCHEMA SCEMA ELETTRICO 21464 63662 63678 51461 96130 51461 71542 M 51021 71873 71513 97799C 97798C 97801C 97155C 97797C 5 4 7 2 97796C 51978 201 AC DC 21464 63662 63678 51461 96130 51461 71542 M 510...

Страница 18: ...Grado de protecci n Beschermingsklasse Grado di protezione IP21 Dimensions Lxlxh Dimensions Lxlxh Abmessung LxBxH Dimensiones Lxlxh Afmetingen Lxlxh Dimensioni Lxlxh 24 x 41 x 36 cm Poids Weight Gewi...

Страница 19: ...ions Lxlxh Abmessung LxBxH Dimensiones Lxlxh Afmetingen Lxlxh Dimensioni Lxlxh 24 x 43 x 50 cm Poids Weight Gewicht Peso Gewicht Peso 20 5 Kg Les facteurs de marche sont r alis s selon la norme EN6097...

Страница 20: ...nsion assign e d alimentation Rated power supply voltage Netzspannung Tensi n de la red Netspanning Tensione nominale di alimentazione I1max Courant d alimentation assign maximal valeur efficace Maxim...

Страница 21: ...rf gbar siehe Titelseite Equipo conforme a los requisitos brit nicos La Declaraci n de Conformidad Brit nica est disponible en nuestra p gina web v ase la portada Materiaal conform aan de Britse eisen...

Страница 22: ...i sicurezza costituito dalla presa elettrica in coordinazione con l installazione elettrica domestica L utente deve assicurarsi dell acces sibilit della presa Refroidissement Cooling K hlung Refrigera...

Отзывы: