background image

  WARNING - SAFETY RULES

GENERAL INSTRUCTIONS

Read and understand the following safety instructions before use.

Any modification or updates that are not specified in the instruction's manual should not be undertaken.

The manufacturer is not liable for any injury or damage caused due to non-compliance with the instructions featured in this manual. In the event of 

problems or uncertainties, please consult a qualified person to handle the installation properly.

ENVIRONMENT

This equipment must only be used for welding operations in accordance with the limits indicated on the descriptive panel and/or in the user manual.  

Safety instructions must be followed. In case of improper or unsafe use, the manufacturer cannot be held liable.

This equipment must be used and stored in a room free from dust, acid, flammable gas or any other corrosive agent.  Operate the machine in an 

open, or well-ventilated area.

 

Operating temperature:

Use between -10 and +40°C (+14 and +104°F).

Storage between -20 and +55°C (-4 and 131°F).

Air humidity:

Lower or equal to 50% at 40°C (104°F).

Lower or equal to 90% at 20°C (68°F).

Altitude:

Up to 1000 meters above sea level (3280 feet).

INDIVIDUAL PROTECTIONS AND OTHERS

Arc welding can be dangerous and can cause serious injury or even death.

Welding exposes the user to dangerous heat, arc rays, electromagnetic fields, risk of electric shock, noise and gas fumes. People wearing pacemakers 

are advised to consult a doctor before using the welding machine. To protect oneself as well as others, ensure the following safety precautions are 

taken :

In order to protect you from burns and radiations, wear clothing without turn-up or cuffs. These clothes must be insulating, dry, 

fireproof, in good condition and cover the whole body.

Wear protective gloves which guarantee electrical and thermal insulation. 

Use sufficient welding protective gear for the whole body: hood, gloves, jacket, trousers... (varies depending on the application/

operation). Protect the eyes during cleaning operations. Contact lenses are prohibited during use.

It may be necessary to install fireproof welding curtains to protect the area against arc rays, weld spatter and sparks. Inform the 

people around the working area to never look at the arc nor the molten metal, and to wear protective clothes.

Ensure ear protection is worn by the operator if the work exceeds the authorised noise limit (the same applies to any person in 

the welding area).

Keep hands, hair and clothes away from moving parts such as fans, and engines.

Never remove the safety covers from the cooling unit when the machine is plugged in. The manufacturer is not liable for any injury 

or damage due to non-compliance with the safety precautions.

Parts that have just been welded will be hot and may cause burns when touched. During maintenance work on the torch or the 

electrode holder, you should make sure it's cold enough and wait at least 10 minutes before any intervention. When using a wa

-

ter-cooled torch, make sure that the cooling unit is switched on to avoid any burns that could potentially be caused by the liquid. 

It is important to secure the working area before leaving it to ensure protection of the goods and the safety of people.

   Fumes, gas and dust produced during welding are hazardous to health.  It is mandatory to ensure adequate ventilation and/or extraction 

to keep fumes and gas away from the work area. Using an air fed welding helmet is recommended in case of insufficient ventilation in the workplace.

Check that the suction is effective by referring to the recommended safety regulations.

Precautions must be taken when welding in small areas, and the operator will need supervision from a safe distance. In addition, the welding of certain 

materials containing lead, cadmium, zinc, mercury or beryllium may be particularly harmful.

Also remove any grease on the metal pieces before welding.

Gas cylinders must be stored in an open or ventilated area. They must be stored vertically and held by a support or trolley to limit the risk of fall.

WELDING FUMES AND GAS

16

EN

Translation of the original instructions

PROTIG 201 AC/DC - 201L AC/DC

Содержание PROTIG 201 AC/DC

Страница 1: ...4 09 2020 FR 2 15 97 104 EN 16 28 97 104 PROTIG 201 AC DC 201L AC DC DE 29 41 97 104 ES 42 54 97 104 RU 55 68 97 104 www gys fr Find more languages of user manuals on our website IT 83 96 97 104 NL 69...

Страница 2: ...eyes during cleaning operations Contact lenses are prohibited during use It may be necessary to install fireproof welding curtains to protect the area against arc rays weld spatter and sparks Inform t...

Страница 3: ...e that the cable cross section is adequate with the usage extensions and welding cables Always wear dry clothes which are in good condition in order to be isolated from the welding circuit Wear insula...

Страница 4: ...tween the conduct and the casing of the welding current source b Maintenance of the arc welding equipment The arc welding machine should be subject to a routine maintenance check according to the reco...

Страница 5: ...Flexible Voltage feature and needs to be powered by an earthed electrical installation between 110V and 240V 50 60Hz For intensive use at 110 V replace the original plug with a 32 A plug protected by...

Страница 6: ...on the control board red box on diagram below n 2 4 Turn the switch located on this control card ON The red LED switches off 5 The VRD function is activated 6 Screw the power source cover back on 7 O...

Страница 7: ...ot modes AC DC Choose between TIG DC TIG AC and TIG AC Easy AC Select the parameter to be adjusted between Frequency and Balance A V display selection By default the welding current is displayed on th...

Страница 8: ...e current setting It is also possible to press another key related to another parameter to adjust it The buttons concerned are the BP1 to BP5 and the adjustment BP in AC If no action is performed on t...

Страница 9: ...setting by pressing the A V button ISO Set the welding end current it is set as a percentage of the welding current setpoint It can be adjusted between 10 and 200 Validate the entered setting by press...

Страница 10: ...rch trigger the arc starts without contact using High Frequency impulsions 3 The initial welding current flows the weld will be continues according to the welding cycle 1 Position the torch nozzle and...

Страница 11: ...37 3 2 mm 60 A 180 A 43 4 0 mm 75 A 200 A 50 With this mode the frequency value is related to the welding current value as follows Current A Frequency Hz 10 40 117 41 90 100 91 140 79 141 170 70 171 2...

Страница 12: ...ay With the incremental encoder select a job number Only numbers associated with existing jobs can be displayed Press successively 3 times on the JOB button The selected job is now deleted and the pow...

Страница 13: ...s from I welding to I cold The secondary button is released the current switches from I cold to I welding T3 A long press on the main button 0 5 sec the cycle switches to DownSlope and stops in the I_...

Страница 14: ...of the current from the minimum current to 100 of the set intensity In TIG the welding machine only operates in 2T mode The upslope and downslope are not automatically managed by the current source a...

Страница 15: ...tion cable pedal connector Kabel Anschluss f r Fernsteuerung Cable conector pedal Kabel aansluiting pedaal Fasciocavo connettore pedale 71513 5 lectrovanne Solenoid valve Magnetventil Electrov lvula M...

Страница 16: ...Anschluss Conexi n gas Gasaansluiting Connessione gas 55090 19 Connecteur torche faisceau Torch connection Connection cable Brenner Anschluss Zwischenschlauchpaket Conector antorcha cable de uni n Aan...

Страница 17: ...E SCHEMA SCEMA ELETTRICO 21464 63662 63678 51461 96130 51461 71542 M 51021 71873 71513 97799C 97798C 97801C 97155C 97797C 5 4 7 2 97796C 51978 201 AC DC 21464 63662 63678 51461 96130 51461 71542 M 510...

Страница 18: ...Grado de protecci n Beschermingsklasse Grado di protezione IP21 Dimensions Lxlxh Dimensions Lxlxh Abmessung LxBxH Dimensiones Lxlxh Afmetingen Lxlxh Dimensioni Lxlxh 24 x 41 x 36 cm Poids Weight Gewi...

Страница 19: ...ions Lxlxh Abmessung LxBxH Dimensiones Lxlxh Afmetingen Lxlxh Dimensioni Lxlxh 24 x 43 x 50 cm Poids Weight Gewicht Peso Gewicht Peso 20 5 Kg Les facteurs de marche sont r alis s selon la norme EN6097...

Страница 20: ...nsion assign e d alimentation Rated power supply voltage Netzspannung Tensi n de la red Netspanning Tensione nominale di alimentazione I1max Courant d alimentation assign maximal valeur efficace Maxim...

Страница 21: ...rf gbar siehe Titelseite Equipo conforme a los requisitos brit nicos La Declaraci n de Conformidad Brit nica est disponible en nuestra p gina web v ase la portada Materiaal conform aan de Britse eisen...

Страница 22: ...i sicurezza costituito dalla presa elettrica in coordinazione con l installazione elettrica domestica L utente deve assicurarsi dell acces sibilit della presa Refroidissement Cooling K hlung Refrigera...

Отзывы: