DIRECTIONS FOR USE (FIG IV)
The NOVOMIG feature allows you to adjust the voltage and the wire speed.
• The voltage (button A/ B)
• Wire speed - adjust the regulator (1) to the colour zone indicated.
Examples :
To weld 1.0mm thick steel :
• Move button (2) to the « A » position
• Move the regulator (1) to the zone of lightest colour and adjust « by sound » if required
ADVICE AND THERMAL PROTECTION
- Respect the normal rules of welding
- Leave the machine plugged in after welding to allow it to cool
- Thermal Protection : The LED will illuminate. Cooling will take between 10 and 15 minutes depending on the
ambient temperature.
- The excessive bending of the cable will disrupt the wire feed.
- The torch cable must be maintained in a straight position throughout inner liner loading to avoid permanent da
-
mage.
- Thermal protection: the indicator lights up and the cooling time is 5 to 10 minutes depending on the ambient tempe
-
rature.
Splashes :
- During welding, the spatters can easily damage the torch and welding equipment. To avoid constraints to the cable,
the welding arc’s stability. Any spatter on the nozzle or difuser should be cleaned as soon as possible.
- The spatters accumulated in the nozzle that are not cleaned in due course will cause a short-circuit which could
damage the torch elements.
- The use of anti-spatter agenst to reduce the spatters is recommended. In order to avoid to deteriorate the torch,
do not use a cutting tool to clean th splashes.
- The torch mustn’t be used for heating and cutting.
- The torch cable mustn’t be used for pulling heavy objects (such as the welding station).
- The torch must be clean and tidy when the welding operation has ended.
- If the torch is not used for more than one week, the welding wire must be removed to avoid the increase of friction
inside the intern sheath wire (by wire oxidation).
- Additonal external protections are necessary when the torch is used in the following cases:
a. High risk of electric shock ;
b. Combustible environment ;
c. Work position at height ;
d. Noisy environment ;
e. Environment with airstream ;
f. Closed tanks.
TECHNICAL CHARACTERISTICS OF THE TORCH
Process
MIG/MAG
Guide method
Manual
Nominal/Peak voltage
113 V
Max Welding current (A)
80 A
Operating factor to 40°C
Imax
35%
Diameter of the applicable welding wire
Ø0.6~1.0 mm
Cable length
2.2 m
Type of gas
Without gas only
Gas flow rate (l/mn)
Not applicable
Cooling mode
Free cooling
Applied standard
EN60974-7: 2013
Содержание NOVOMIG 110
Страница 30: ...30 NOVOMIG 110 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Страница 31: ...31 NOVOMIG 110 RU 11 2 CLASSIFICATION CEM DU MAT RIEL A CEI 61000 3 12 CEM EMF...
Страница 32: ...32 NOVOMIG 110 RU EMF b c d e f g h 10 CISPR 11 2009 a...
Страница 33: ...33 NOVOMIG 110 RU b c d e f 10 IP21 12 5...
Страница 37: ...37 NOVOMIG 110 RU NO GAS...
Страница 53: ...53 NOVOMIG 110 FIG I FIG II 3 5 7 10 9 2 1 6 8 4...
Страница 54: ...54 NOVOMIG 110 110A MIG NO GAS 0 9 mm NO GAS A A 1 A B 0 8 1 5 2 3 4 mm B B A B FIG IV FIG III 3 2 1...