background image

16

NEOPULSE 400

EN

CONNECTIONS AND RECOMMENDATIONS

The connection between the welding machine and the wire feeder must be done while the power supply is off.

Open the access panel and pass the interconnection cable 

through the circular opening at the back of the wire feeder.

Lock the interconnection cable on the wire feeder’s panel by 

twisting it clockwise by 1/4.

Lock the support using the screw supplied with the connection 

cable.

Pass the interconnection cable through the trolley.

Lock the interconnection cable on the trolley by twisting it 

clockwise by 1/4.

Lock the support using the screw supplied with the connection 

cable.

 

POWER SUPPLY – STARTING UP

This equipment is fitted with a 32A / 5 pin socket (3P+N+PE) which must be connected to a three-phase 400V (50 - 60 Hz) power supply fitted with 

four wires and one earthed neutral.

The absorbed effective current (I1eff) is displayed on the machine, for optimal use. Check that the power supply and its protection (fuse and/or 

circuit breaker) are compatible with the current required by the machine. In some countries, it may be necessary to change the plug to allow the use 

at maximum settings.

• The machine ie designed to work on a 400V +/- 15%  power supply. • The device turns into protection mode if the power supply tension below 330V 

RMS or over 469V RMS.. (To indicate this default, the wire feeder’s screen displays an error code, check the instruction manual).

• The start is done via an on / off switch (6 - FIG 1) set to I, and the stop is done by switiching it to O. Warning ! Never disconnect the power supply 

when the machine is on.

• Cooling fan management : This welding machine features an intellingent cooling fan system, in order to minimise noise. The fans will adjust their 

speed depending on the current use and ambient temperature. They may be off in MIG mode.

CONNECTION TO A GENERATOR

The machine can work with generators as long as the auxiliary power matches these requirements :

- The voltage must be AC, always superior to 400Vac ±15%, and the peak voltage below 700V,

- The frequency must be between 50 and 60 Hz.

It is imperative to check these requirements as several generators generate high voltage peaks that can damage these machines.

USE WITH EXTENSION CABLES

All extension cables must have an adequate size and section, relative to the machine’s voltage  . 

Use an extension that complies with national safety regulations.

Current input

Extension selection (<45m)

400V

6 mm²

Содержание NEOPULSE 400

Страница 1: ...73502_V2_19 07 2017 FR 2 3 10 59 64 NEOPULSE 400 www gys fr EN 2 11 18 59 64 RU 2 35 42 59 64 NL 2 43 50 59 64 IT 2 51 58 59 64 ES 2 27 34 59 64 DE 2 19 26 59 64...

Страница 2: ...NEOPULSE 400 FIG 1 1 FIG 2 2 3 4 5 6 7 1 2 3...

Страница 3: ...elon les applications Prot gez vos yeux lors des op rations de nettoyage Les lentilles de contact sont particuli rement proscrites Il est parfois n cessaire de d limiter les zones par des rideaux igni...

Страница 4: ...u r seau et attendre 2 minutes afin que l ensemble des condensateurs soit d charg Ne pas toucher en m me temps la torche ou le porte lectrode et la pince de masse Veillez changer les c bles torches si...

Страница 5: ...abricant Si des interf rences se produisent il peut tre n cessaire de prendre des mesures de pr vention suppl mentaires telles que le filtrage du r seau public d alimentation Il convient d envisager d...

Страница 6: ...de ce mat riel ENTRETIEN CONSEILS L entretien ne doit tre effectu que par une personne qualifi e Un entretien annuel est conseill Couper l alimentation en d branchant la prise et attendre deux minutes...

Страница 7: ...ge ref 036277 95 mm2 Mig lift pro ref 046429 C ble inversion polarit 1 3 m ref 033689 Commande d port e analogique RC HA2 ref 047679 Commande d port e num rique RC HD1 ref 047662 La liaison entre le N...

Страница 8: ...ctionner sur une tension lectrique 400V 15 Elle se met en protection si la tension d alimentation est inf rieure 330 Veff ou sup rieure 490Veff un code d faut apparaitra sur l affichage du d vidoir s...

Страница 9: ...se r f rer au manuel d instruction du groupe de froid Il faut s assurer que le groupe de refroidissement est teint avant la d connexion des tuyaux d entr e et de sortie de liquide de la torche Le liq...

Страница 10: ...poste n est pas utilis Ne pas brancher la torche lorsque le poste est utilis en soudage MMA ARRI RE DU POSTE AVANT DU POSTE DESCRIPTION 1 Commande 3 Puissance facultatif CONDITIONS DE GARANTIE FRANCE...

Страница 11: ...ody hood gloves jacket trousers variable depending on the application operation Protect your eyes during cleaning operations Do not operate whilst wearing contact lenses It may be necessary to install...

Страница 12: ...scharged Do not touch the torch or electrode holder and earth clamp at the same time Damaged cables and torches must be changed by a qualified professional Make sure that the cable cross section is ad...

Страница 13: ...If interferences occur it may be necessary to take additional preventive measures such as the filtering of the power suplly network Consideration should be given to shielding the power supply cable i...

Страница 14: ...rly maintenance is recommended Ensure the machine is unplugged from the mains and wait for two minutes before carrying out maintenance work DANGER High Voltage and Currents inside the machine Remove t...

Страница 15: ...r kit ref 046580 Slinging support ref 036277 95 mm2 Mig lift pro ref 046429 Polarity reversal cable 1 3 m ref 033689 Analogue remote control RC HA2 ref 047679 Digital remote control RC HD1 ref 047662...

Страница 16: ...to allow the use at maximum settings The machine ie designed to work on a 400V 15 power supply The device turns into protection mode if the power supply tension below 330V RMS or over 469V RMS To ind...

Страница 17: ...ng unit is switched off before disconnecting the inlet and outlet hoses for torch liquid The coolant is harmful and irritates the eyes the mucus membranes and the skin Hot liquid may cause burns CONNE...

Страница 18: ...3689 MMA WELDING Ensure that the welding polarities and intensities indicated on the electrode packaging are observed Remove the electrode from the electrode holder when the machine is not in use Do n...

Страница 19: ...ungen f hren Die Haut muss durch geeignete trockene Schutzbekleidung Schwei erhandschuhe Ledersch rze Sicherheitsschuhe gesch tzt werden Tragen Sie elektrisch und w rmeisolierende Handschuhe Tragen Si...

Страница 20: ...tikverschluss Garantiesiegel von der Flasche entfernt werden Verwenden Sie ausschlie lich Gas das f r die Schwei arbeit mit den von Ihnen ausgew hlten Materialen geeignet ist ELEKTRISCHE SICHERHEIT Da...

Страница 21: ...en Pr fung des Schwei ger tes Neben der berpr fung des Schwei platzes kann eine berpr fung des Schwei ger tes weitere Problem l sen Die Pr fung solte gem Art 10 der IEC CISPR 11 2009 durchgef hrt werd...

Страница 22: ...iertem und geschultem Fachpersonal durchgef hrt werden Eine j hrliche Wartung wird empfohlen Trennen SIe das Ger t von der Stromversorgung und warten Sie bis der L fter nicht mehr l uft Erst dann d rf...

Страница 23: ...Filterset Art Nr 046580 St nder Art Nr 036277 95 mm2 Ausleger MIG LIFT PRO Art Nr 046429 Verpolungskabel 1 3m Art Nr 033689 Fernregler RC HA2 analog Art Nr 047679 Fernregler RC HD1 digital Art Nr 0476...

Страница 24: ...erfor derlich sein um die maximale Leistung abrufen zu k nnen Das Schwei ger t arbeitet mit einer elektrische Spannung von 400V 15 Unter 330Veff und ber 490Veff wird der Spannungschutz des Ger tes ak...

Страница 25: ...K hlaggregat deaktivieren wollen Lesen Sie die Anleitung des K hlaggregats bevor Sie es Benutzen Das K hlaggregat muss ausgeschaltet sein wenn Sie die K hlschl uche anschliessen oder entfernen Die K...

Страница 26: ...m E Hand Schwei en benutzt wird GER TER CKSEITE GER TEVORDERSEITE BESCHREIBUNG 1 Steuerung 3 Leistung optional GARANTIEBEDINGUNGEN Die Garantieleistung des Herstellers erfolgt ausschlie lich bei Fabri...

Страница 27: ...ficiente variable seg n aplicaciones Prot jase los ojos durante operaciones de limpieza Las lentillas de contacto est n particularmente prohibidas A veces es necesario delimitar las zonas mediante cor...

Страница 28: ...conectarlo de la red el ctrica y esperar dos minutos para que el conjunto de los condensadores se descarguen No toque al mismo tiempo la antorcha o el portaelectrodos y la pinza de masa Cambie los cab...

Страница 29: ...aciones del fabricante Si se produjeran interferencias podr a ser necesario tomar medidas de prevenci n suplementarias como el filtrado de la red p blica de alimentaci n el ctrica Se recomienda apanta...

Страница 30: ...ntenimiento s lo debe realizarse por personal cualificado Se aconseja efectuar un mantenimiento anual Corte el suministro el ctrico luego desconecte el enchufe y espere 2 minutos antes de trabajar sob...

Страница 31: ...de suspensi n ref 036277 95 mm2 Mig lift pro ref 046429 Cable de inversi n de polaridad 1 3 m ref 033689 Control remoto anal gico RC HA2 ref 047679 Control remoto digital RC HD1 ref 047662 La uni n e...

Страница 32: ...ndiciones de uso m ximas El generador de potencia funciona sobre una tensi n el ctrica de 400V 15 Se pone en protecci n si la tensi n de la red el ctrica es inferior a 330Veff o superior a 490Veff un...

Страница 33: ...instrucciones del grupo de refrigeraci n Se debe asegurar que el equipo de refrigeraci n est apagado antes de la desconexi n de los tubos de entrada y salida de l quido de la antorcha El l quido de re...

Страница 34: ...ARTE DELANTERA DEL EQUIPO DESCRIPCI N 1 Control 2 Gas 3 Potencia 4 Refrigeraci n 5 6 Cable de inversi n de polaridad opci n ref 033689 SOLDADURA MMA Respete las polaridades e intensidades de soldadura...

Страница 35: ...35 NEOPULSE 400 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 2000 6500 10...

Страница 36: ...36 NEOPULSE 400 RU 11 2 A CEI 61000 3 12 EMF EMF...

Страница 37: ...37 NEOPULSE 400 RU b c d e f g h 10 CISPR 11 2009 a b c d e f...

Страница 38: ...38 NEOPULSE 400 RU 1 10 IP23 12 5 60 IP23 GYS 2 FIG 1 1 5 2 6 ON OFF 3 IHM 7 4 NEOPULSE 400 MIG MAG MMA IHM 2 1...

Страница 39: ...43831 7 MIG MAG 500 A 4 041004 500 A 3 046160 047020 047037 046580 036277 95 mm2 Mig lift pro 046429 1 3 033689 rc hA2 047679 rc HD1 047662 NEOPULSE 400 NEOFEED 4L 5m 70mm 047587 10m 70mm 047594 95mm...

Страница 40: ...40 NEOPULSE 400 RU 1 4 1 4 32A 3 3 EN 60309 1 400 50 60 I1eff 400 15 330Veff 490Veff 6 FIG 1 I O MIG 400Vac 15 700 50 60...

Страница 41: ...41 NEOPULSE 400 RU 45 400B 6 1 2 3 4 5 6 7 8 9 10 A C B D E F G H J K A B D E F G H J K C 53056 Y Z A B 24V M24V M48V 48V NEOCOOL MIG MAG MIG MAG 1 2 3 4 5...

Страница 42: ...42 NEOPULSE 400 RU MIG MAG 033689 1 2 3 4 5 6 033689 MMA X MMA 1 3...

Страница 43: ...edt afhankelijk van de lastoepassing Bescherm uw ogen tijdens schoonmaakwerkzaamheden Contactlenzen zijn uitdrukkelijk verboden Soms is het nodig om het lasgebied met brandwerende gordijnen af te sche...

Страница 44: ...rodehouder en de massa klem aan Zorg ervoor dat als de kabels of toortsen beschadigd zijn deze worden vervangen door gekwalificeerde en bevoegde personen Gebruik alleen kabels verlengsnoeren en laskab...

Страница 45: ...van het openbare stroomnetwerk Er kan overwogen worden om de voedingskabel van de lasinstallatie af te schermen in een metalen leiding of een equivalent daarvan Het is wenselijk de elektrische contin...

Страница 46: ...dt aangeraden Haal de stekker uit het stopcontact om de elektriciteitsvoorziening te onderbreken en wacht twee minuten alvorens werkzaamheden op het apparaat te verrichten De spanning en de stroomster...

Страница 47: ...0 Steunen voor hijsen of heffen art code 036277 95 mm2 Mig lift pro Art code 046429 Kabel politariteitsomkering 1 3 m Art code 033689 Analoge afstandsbediening rc hA2 Art code 047679 Digitale afstands...

Страница 48: ...e functioneren met een elektrische spanning van 400V 15 De stroombron stelt zichzelf in thermische beveiliging wanneer de voedingsspanning lager is dan 330 Veff of hoger dan 490 Veff een storingscode...

Страница 49: ...eren de handleiding van de koelgroep De gebruiker moet zich ervan verzekeren dat de koelgroep uitgeschakeld is alvorens de slangen aan de in en uitgang van de toorts af te koppelen De koelvloeistof is...

Страница 50: ...T APPARAAT OMSCHRIJVING 1 Bediening 2 Gas 3 Vermogen 4 Afkoeling 5 6 Polariteit omkerende kabel optioneel art code 033689 MMA LASSEN Respecteer de aangegeven polariteiten en las intensiteiten vermeld...

Страница 51: ...seconda delle applicazioni Proteggete i vostri occhi durante le operazioni di pulizia Le lenti a contatto sono particolarmente sconsigliate Potrebbe essere necessario limitare le aree con delle tende...

Страница 52: ...orcia e il morsetto di massa Far sostituire i cavi e le torce danneggiati solo da persone abilitate e qualificate Dimensionare la sezione dei cavi prolunga e cavi di saldatura in base all applicazione...

Страница 53: ...co o equivalente di un materiale di saldatura ad arco fissati stabilmente Converrebbe anche assicurarsi della continuit della schermatura elettrica su tutta la sua lunghezza E conveniente collegare la...

Страница 54: ...ne staccando la presa e attendere due minuti prima di lavorare sul dispositivo All interno le tensioni e l intensit sono elevate e pericolose Regolarmente togliere il coperchio e spolverare con l aiut...

Страница 55: ...if 046580 Supporto imbragatura rif 036277 95 mm2 Mig lift pro rif 046429 Cavo inversione polarit 1 3 m rif 033689 Telecomando analogico rc hA2 rif 047679 Telecomando numerico rc HD1 rif 047662 Il coll...

Страница 56: ...lla rete elettrica 400V 15 Si mette in protezione se la tensione di alimentazione inferiore a 330 Veff o superiore a 490Veff un codice errore apparir sullo schermo del trainafilo separato fare riferim...

Страница 57: ...ne fare riferimento al manuale d istruzioni dell unit di raffreddamento Bisogna assicurarsi che l unit di raffreddamento sia spenta prima della disconnessione dei tubi d entrata e di uscita di liquido...

Страница 58: ...TERIORE DEL DISPOSITIVO DESCRIZIONE 1 Comando 2 Gas 3 Potenza 4 Raffreddamento 5 6 Cavo d inversione della polarit opzione rif 033689 SALDATURA MMA Rispettare le polarit e l intensit di saltatura indi...

Страница 59: ...59 NEOPULSE 400 PI CES DE RECHANGE SPARE PARTS ERSATZTEILE PIEZAS DE RECAMBIO ERSATZTEILE RESERVE ONDERDELEN PEZZI DI RICAMBIO 14 4 1 20 19 21 11 12 16 22 15 13 18 5 17 27 10 9 3 26 8 24 25 6 2 23 7...

Страница 60: ...edingscircuit n 2 Circuito d alimentazione ausiliaria n 2 97288 13 Commutateur triphas Three phase switch Conmutador trif sico Dreiphasiger Schalter Driefasige schakelaar Commutatore trifase 51061 14...

Страница 61: ...SCH SCHEMA SCHEMA ELETTRICO 52196 51061 21470 97277C 97278C 97289C 97288C 97269C 97363C 91805 51016 51016 97274C 97276C 97276C 97372C 97372C 97527 51478 51478 97364C 96119 96121 64460 64664 52104 5210...

Страница 62: ...cles are measured according to standard EN60974 1 40 C and on a 10 min cycle While under intensive use to duty cycle the thermal protection can switch on in that case the arc stops and the indicator s...

Страница 63: ...ura in un ambiente con grandi rischi di scosse elettriche La fonte di corrente non deve essere localizzata in tale posto IP23 Protecteur contre l acc s aux parties dangereuses des corps solides de 12...

Страница 64: ...he Gemeenschap merkteken van overeenstemming Marchio di conformit EAC Comunit economica Eurasiatica Ce mat riel fait l objet d une collecte s lective selon la directive europ enne 2012 19 UE Ne pas je...

Отзывы: