EN
11
Operating manual
GYSFLASH S 1.12 PL
Translation of the original
instructions
Step
1
: Analysis
Analyses the battery state (charge level, polarity inversion,
wrong battery…)
Step
5
: Charge
(1 A)
Maximum current fast charge to reach an 80% charge level.
Step
2
: Recovery
(0.5 A)
Recovering damaged elements due to a prolonged deep
discharge.
Step
6
: Absorption
(14.4 V or 14.7 V with AGM option)
Constant voltage charging to bring the charge level to 100%.
Step
3
: Test
Sulfated battery test
Step
7
: Floating charge
(13.6 V)
Maintains battery charge level at its maximum.
Step
4
: Desulfation
(15.8 V)
Battery desulfation algorithm.
• Lithium charging curve :
The Gysflash S 1.12 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your LFP battery.
U
I
1
2
3
4
5
6
7
Analysis
Recovery
Charge
Absorption
Supplement
Equalization /
balancing
Floating charge
< 1s
Max 5 min
Max 30 h
Max 20 h
3 min
Max 10 h
Max 2 h
No limit
(maintenance every 10 days)
CHARGE
OK
Le
d
8
Test
Equalizing Battery System
Step
1
: Analysis
Analyses the battery state (charge level, polarity inversion, wrong battery…)
Step
5
: Test
Charge conservation test.
Step
2
: Recovery
(0.2 A)
Recovery algorithm following a deep discharge.
Step
6
: Supplement
Reduce current charge to reach 100% charge
level.
Step
3
: Charge
(1 A)
Fast charging at maximum current allowing to reach 90% of the charge level.
Step
7
: Equalization / balancing
(14.4 V)
Balancing the battery cells
Step
4
: Absorption
(13.8 V)
Constant voltage charging to bring the charge level to 98%.
Step
8
: Floating charge
(13.8 V)
Maintain the battery charge level at its maximum
with maintenance charging every 10 days.
• Estimated charge time
Lead-acid
Lithium
Battery capacity
2 Ah
10 Ah
20 Ah
32 Ah
1 Ah
(3 Ah EqPb*)
5 Ah
(15 Ah EqPb*)
10 Ah
(30 Ah EqPb*)
20 Ah
(60 Ah EqPb*)
Charging time
0% >> 90%
2 h
9 h
18 h
29 h
1 h 30
4 h 30
8 h 30
16 h
*Lead battery equivalent: A lithium battery has better starting performance (CCA) than a lead battery. This is why some lithium battery manufac-
turers indicate the battery lead equivalent (EqPb) corresponding to the capacity of a lead-acid battery with the same starting performance. For
instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid battery of around 30 Ah.
Содержание 070851
Страница 24: ...8 60 C II 24 GYSFLASH S 1 12 PL...
Страница 28: ...8 60 28 GYSFLASH S 1 12 PL...
Страница 29: ...29 GYSFLASH S 1 12 PL JP II...
Страница 35: ......