The cover must be placed on the other side of the pusher pad.
The gas-shielding cover must not be fitted to the earthing pad when welding without a gas shield.
• Position the pad (equipped with its cover) to the end of the earthing
rods and then screw in the two clamping screws. We recommend posi
-
tioning the pad with the clamping screws facing the bottom of the gun
to keep the positioning markings clearly visible.
Note: Using the gas protection and earthing pad is not necessary when
welding a pulling ring.
Positioning
markings
clamping screw
ERROR MESSAGE, ANOMALIES, CAUSES AND SOLUTIONS
This equipment has a fault monitoring system. An error message will be shown on the display screen in the event of a
fault.
Error code
Meaning
Causes
Solutions
DEFAUT THERMIQUE
Thermally protecting
the machine
Exceeding the duty cycle.
Wait until the message has disappeared
before resuming welding.
DEFAUT SECTEUR
Mains voltage fault Mains voltage out of range
or missing a phase.
Have your electrical system checked by an
authorised person. The voltage between
phase and neutral must be between 200 -
265 VAC for a 230 VAC network.
TOUCHE APPUYEE
Keypad fault
A key on the keypad has
been pressed when the
product is switched on.
Have the keypad checked by a qualified
person.
DEFAUT COM.
Gun communication
fault
The communication
between the gun and the
machine is not functio-
ning.
Reconnect the gun and turn the welding
machine off and on again. If the fault
persists, have the product checked by a
qualified technician.
DEFAUT THERMIQUE
The gun’s thermal
protection.
Exceeding the duty cycle.
Wait until the message has disappeared
before resuming welding.
DEFAUT MOTEUR
Gun motor fault.
The gun’s mechanism is
blocked.
Reconnect the gun and turn the welding
machine off and on again. If the fault per
-
sists, have the gun checked by a qualified
technician.
Note: any intervention that requires opening up the product and checking the electrical system must be carried out by