![GYS 069824 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/gys/069824/069824_operating-manual_2281113029.webp)
EN
29
Operating manual
GYSPOT COMBI ARCPULL
Translation of the original
instructions
To increase or decrease the arc time (value
t
ms
I
A
100
100
zone de
message
), press the G+ and G- keys.
To increase or decrease the arc current (value
t
ms
I
A
100
100
zone de
message
), press keys D+ and D-.
To change the other manual welding settings (current and welding stage timings) please refer to the chapter ‘Manual
Settings’.
MAIN MENU
To access the main menu from both SYNERGY and MANUAL mode, press the Menu/Enter button
Menu Principal
> Réglages
Mode Manuel
Configuration
Press the G+ and G- keys to move the cursor. Select the item by pressing the Menu/Enter
button
.
• ‘Settings’ will access the welding settings (synergic or manual).
• MANUAL mode’ / ‘SYNERGY mode’ will change the device’s welding mode (SYNERGY
mode <->MANUAL mode).
• ‘Configuration’ provides access to the appliance’s advanced settings (languages, gas ma
-
nagement and data, etc.).
Press the return button
to return to the welding screen.
SYNERGY MODE SETTINGS
Réglages Synergie
> Matériau > Fe
Gaz ON
Electrode anneau
EP. élec. 1.5 mm
Press the G+ and G- keys to move the left cursor (materials, gas, attachment type and
size). Press the D+ and D- keys to change the values of each item.
Pressing the Menu/Enter
button will confirm the SYNERGY mode settings and return
the machine to the synergy welding screen.
Press the return button
to discard the settings and return to the main menu.
MANUAL MODE SETTINGS
Réglages Manuel
Amorce > Q = 0
Press the G+ and G- keys to successively scroll through the
different arc values (ignition
and fastening coefficients, timings, currents and arc height) of
the welding process (see
the ‘Drawn-Arc Welding’ chapter).
Press the D+ and D- keys to
modify the indicated values (coefficients, timings, current and
arc height).
Pressing the Menu/Enter
button will confirm the manual settings and return the machine to the manual welding
screen.
Press the return button
to discard the settings and return to the main menu.
Setting range in MANUAL mode
Comments
Ignition
-10 to 10 (default value 0)
The default value ensures the best possible ignition without the
risk of breaking the arc when the attachment is lifted whilst also
limiting the short-circuit current.
Increase the ignition slightly if the arc repeatedly breaks.
Holding the
electrode
10 - 60 A
0 - 200 ms
Arc
0 - 200 A
0 - 500 ms
Start up
-10 to 10 (default value 0)
The default value ensures the best possible attachment of the elec-
trode to the support plate.
0 - 50 ms
Height
0.5 - 5 mm