41
NEOFEED 4W
EN
Settings
Designation
Adjustable
settings
Description & advice
Pre-gas
0 - 60 secs.
Torch purge time and to protect the area with gas before ignition
Welding current
5 - Imax
Welding current.
Pulse duration
, 0 - 60
secs.
Pulsation phase controlled manually or for a defined duration
Pulse frequency
0.1 - 2500 Hz
Pulse frequency
Non-pulsed duration
, 0 - 60
secs.
Smooth current phase controlled manually or for a defined duration
Post-gas
0 - 60 secs.
Duration for which gas is released after the arc has stopped. It protects the weld pool
and the electrode against oxidisation when the metal is cooling down.
Access to some welding parameters depends on the selected display mode: Settings/User Level: Easy, Expert, Advanced.
• Welding in E.TIG mode
This mode allows constant power welding by measuring arc length variations in real time to ensure constant bead width and penetration. In case the
assembly requires the welding power to be controlled, the E.TIG mode can be used as it is designed to ensure that the welding power remains the
same regardless of the position of the torch.
Standard
(constant current)
E-TIG
(constant power)
2 mm
D
10 mm
D
5 mm
D
2 mm
D
5 mm
D
10 mm
D
TRIGGER FUNCTIONS
2T MODE
t
t
t
t
t
t
T2
T1
Main button
T3
T1
Main button
T2
T4
T3
T1
Main button
T2
T4
>0.5s
<0.5s
<0.5s
T1 - The main button is pressed, the welding cycle starts (PreGas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped
(DownSlope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the secondary
button works like the main button.
4T MODE
t
t
t
t
t
t
T2
T1
Main button
T3
T1
Main button
T2
T4
T3
T1
Main button
T2
T4
>0.5s
<0.5s
<0.5s
T1 - The main button is pressed, the cycle starts at PreGas and
stops in the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope
and in welding.
T3 - The main button is pressed, the cycle switches to DownSlope
and stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
Nb : for torches, double button and double button with potentiome-
ter
=> command « up/welding current » and active potentiometer,