![GW Instek GDS-1000B Series Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/gw-instek/gds-1000b-series/gds-1000b-series_programming-manual_2280038087.webp)
COMMAND DETAILS
87
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:FREQuency?
>1.0E+3
Selects Channel 1, and then measures the
frequency.
:MEASure:NWIDth
Description
Returns the first negative pulse width timing.
Syntax
:MEASure:NWIDth{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter <NR3>
Returns the negative pulse width in
seconds.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:NWIDth?
4.995E-04
Selects Channel 1, and then measures the negative
pulse width.
:MEASure:PDUTy
Description
Returns the positive duty cycle ratio as percentage.
Syntax
:MEASure:PDUTy{?}
Related
commands
:MEASure:SOURce<X>
Return parameter <NR3>
Returns the positive duty ratio.
Query
Query