![GW Instek GDS-1000B Series Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/gw-instek/gds-1000b-series/gds-1000b-series_programming-manual_2280038070.webp)
GDS-1000B Programming Manual
70
Example
:
CURSor:XY:RECTangular:X:DELta?
80.0E-3
Returns the horizontal delta as 80mV.
:CURSor:XY:RECTangular:Y:POSition<X>
Description
Sets or queries the vertical position in XY mode for
the
Y
rectangular coordinates for
cursor 1 or 2.
Syntax
:CURSor:XY:RECTangular:Y:POSition<X> {<NRf>|?}
Parameter
<X>
Cursor 1, 2
<NRf>
Vertical position co-ordinates
Return parameter <NR3> Returns the cursor position.
Example
:CURSor:XY:RECTangular:Y:POSition1 4.0E-3
Sets the Y-coordinate cursor 1 position to
40mV/mV.
:CURSor:XY:RECTangular:Y:DELta
Description
Returns the delta value of cursor 1 and 2 on the Y
coordinate.
Syntax
:CURSor:XY:RECTangular:Y:DELta{?}
Return Parameter <NR3>
Returns the delta value of cursor 1 and 2
as <NR3>.
Example
:
CURSor:XY:RECTangular:Y:DELta?
80.0E-3
Returns the horizontal delta as 80mV.
:CURSor:XY:POLar:RADIUS:POSition<X>
Description
Queries the polar radius position for the specified
cursor in XY mode, where X can be either cursor 1
or 2.
Set
Query
Query
Query