GVP 2221315 Скачать руководство пользователя страница 8

When possible, recharge your batteries when they about 50% discharged or earlier. This 

gives the batteries  a much longer life cycle than recharging  when they are more deeply 

discharged.

Our inverter has a battery low voltage shutdown around 20Vdc.With moderate to heavy 

loads, this will protect against over-discharging the battery. if the inverter is running only 

light loads it is advisable  to recharge  before  the inverter  low voltage  shutdown  point is 

reached.

For more information on maintaining batteries, consult your battery's manufacturer.

For information about our battery chargers, please contact us.

The  battery  s  back  up  time  depends  on  the  battery  capacity(Ah)and  your  appliances 

power (Watt)

The method to calculate the operation time is :

Battery capacity(Ah) x input back up / loads power(W)

For example:

                Battery capacity= 150Ah

                Input Voltage= 12V

                Loading power= 600W

                (150Ah x 12V)/600W= 3H

This section describes the most common problems you may encounter with the operation 

of the inverter along with resolutions.

If you encounter problems other than what is described in this section, contact customer

supporting center.

16.1 COMMON PROBLEMS

16.1.1 Buzz in Audio Equipment

Some inexpensive stereo systems may emit a buzzing noise from their loudspeakers when 

operated  from  the  inverter.  This  occurs  because  the  power  supply  in  the  audio  System 

does not adequately filter the modified sine wave produced by the inverter.

The only solution is to use a sound system that has a high quality power supply.

16.1.2 Television Reception

When  the  inverter  is  operating,  it  can  interfere  with  television  reception  on  some 

channels. If interference occurs, try the following:

14.RECHARGING BATTERIES

15. BATTERY’S CAPACITY CALCULATION

16.TROUBLE SHOOTING

1. Make sure that the chassis ground screw on the rear of the inverter is solidly connected 

to the ground system of your vehicle or home.

2.  Make  sure  that  the  television  antenna  provides  an  adequate  ( snow-free  ) signal  and 

that you are using good quality cable between the antenna and the television.

3.  Keep  the  cables  between  the  battery  and  the  inverter  as  short  as  possible,  and  twist 

them  together  with  two  to  three  twists  per  foot.  (  this  minimizes  radiated  interference 

from the cables.)

Move the television as far away from the inverter as possible.

Do not operate high power loads with the inverter when the television is on.

ELECTRICAL

 

SHOCK HAZARD

Do not disassemble the inverter. It does not contain any user-serviceable parts.

Failure to follow these instructions can result in death or serious injury.

Problem    

Possible Cause

Solution

Low output
voltage

No output
voltage.
Both the 
power
light and fault 
light are off

No output
voltage.
Fault light
is on

Low battery
alarm stays on

Poor DC wiring, Low battery poor 
battery condition

Low input voltage
High input voltage
Thermal shutdown
Unit overload
Output is short circuited

The inverter is off.
No power to the inverter.
The  inverter  could  have  been 
connected  with  reverse  DC  input 
polarity

You  are  using  a  voltmeter  that 
cannot  accurately  read  the  RMS 
voltage of a modified sine wave.
Low  input  voltage  and  the  load  is 
close to maximum allowable power

Use  a  true  RMS  reading  voltmeter  such  as 
the Fluke87.
Check  the  connections  and  cable  to  see  if 
the battery is fully charged.
Recharge the battery if it is low.
Reduce the load.

Recharge the battery, check the connections 
and cable. Make sure the
inverter  is  connected  to  a  correct  battery 
(24V inverter for 24V batteries bank) Allow 
the  unit  to  cool  off.  Reduce  the  load  if 
continuous  operation  is  required.  Improve 
ventilation.  Make  sure  the  inverter  s 
ventilation openings are not obstructed.
Reduce  the  ambient  temperature.  Reduce 
the  load.  Make  sure  the  load  does  not 
exceed the inverter s output rating.
Remove the short circuit

Turn the inverter on.
Check the wiring to the inverter and to
the battery selector switch (if installed).
The inverter has probably been damaged.
Return the unit, damage caused by reverse 
polarity is not covered by the warranty

Use proper cable size and lengths and make 
solid connections 
Charge the battery Install a new battery

16. 2 TABLE 1 TROUBLESHOOTING REFERENCE

Содержание 2221315

Страница 1: ...2221315 Inverter ...

Страница 2: ...ubstandard wiring Make sure that all wiring is in good condition and is not undersized ELECTRICAL SHOCK HAZARD FIRE AND BURN HAZARD EXPLOSION HAZARD Failure to follow these instructions will result in death or serious injury Do not cover or obstruct the air intake vent openings and or install in a zero clearance compartment Do not use transformer less battery chargers in conjunction with the inver...

Страница 3: ... protects the battery from being completely discharged HIGH BATTERY VOLTAGE SHUTDOWN Shuts the inverter down automatically if the input voltage rises to 31 volts or more OVER LOAD SHUTDOWN Shuts the inverter down automatically if the loads connected to the inverter exceed the inverter s operating limits OVER TEMPERATURE SHUTDOWN Shuts the inverter down automatically if its internal Temperature ris...

Страница 4: ... indicates the inverter is operating 7 AC OUTLETS are used to power loads 8 USB port it output DC5V 2 1A for charge for your appliance 9 ON OFF SWITCH turns the Inverter on and off 10 Remote ON OFF connector port is used for connecting the ON OFF remote switch 5 2 POWER SYSTEM CONNECTION EXAMPLE Figure 4 Typical power system designs 5 3 BATTERY REQUIREMENTS Battery type and battery size strongly a...

Страница 5: ...rs on the positive cable line in your power system following these recommendations when you purchasing fuses or circuit breakers Select a fuse or circuit breaker with a maximum rating of 150Adc Determine the short circuit current rating of the battery and choose a battery fuses that withstand the short circuit current that may be generated by the battery 9 INSTALL THE INVERTER Review and follow th...

Страница 6: ...e negative DC input terminal on the inverter 6 Attach the other end of the negative DC input cable to the negative terminal of the battery If you have installed a battery selector switch set it to off when making the connection to prevent sparking NOTE This is last cable connection A spark is normal when you make the connection to This section explains how to operate the inverter efficiently and e...

Страница 7: ...Some induction motors used in freezers pumps and other motor operated equipment require high surge currents to start The inverter may not be able to start some of these motors even though their rated current draw is within the inverter s limits The inverter will normally start single phase induction motors Some equipment may be not work well or damaged by the inverter s modified sine wave output S...

Страница 8: ...na provides an adequate snow free signal and that you are using good quality cable between the antenna and the television 3 Keep the cables between the battery and the inverter as short as possible and twist them together with two to three twists per foot this minimizes radiated interference from the cables Move the television as far away from the inverter as possible Do not operate high power loa...

Страница 9: ...ed by damage may adversely affect human health and harm the environment during recycling WARRANTY CARD 19 WARRANTY AND SERVICE AGREEMENTS This warranty covers only manufacturing defects The appliance must not be modified or altered in any way with regards to both form and function This warranty does not apply in case of improper usage usage that falls beyond normal use as indicated in the user s m...

Отзывы: