![GVP 2221315 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/gvp/2221315/2221315_user-manual_2279944006.webp)
9.4 CONNECT THE DC CABLE
IMPORTANT: Before proceeding, make sure that your DC input cables are properly
terminated with ring connectors appropriate for the size of the cable you are using. We
advise you use the DC input cable inside of our inverters packing.
1. Make sure the inverter's ON/OFF switch is in the off position
2. Working on the inverter's positive DC input terminal first, attach one end of the positive
DC input cable to the positive DC input terminal on the inverter.
IMPORTANT: Do not over tighten the nut on the inverter terminal. Damage to the inverter
terminal may result. However, loose connections can cause excessive voltage drop and
may cause overheated wires and melted insulation.
3. Attach a fuse holder (with an installed fuse) to the other end of the positive battery
cable.
Alternatively, if you using a circuit breaker, install the circuit breaker on the positive
terminal of the battery.
4. Attach the fused end on the positive DC input cable to the positive terminal of the
battery.
Alternatively, if you are using a circuit breaker, attach the other end of the positive DC
input cable to the circuit breaker on the battery.
DC power connection to the inverter must be positive to positive and negative to negative.
A reverse polarity connection (connecting positive to negative) will blow the internal fuse inside the inverter
and can cause damage to the inverter.
Damage caused by a reverse polarity connection is not covered by the warranty.
Failure to follow these instructions can damage the unit and or damage other equipment.
Thoroughly ventilate the battery compartment before proceeding to connect the negative DC input cable to
the battery.
It is always possible that flammable fumes are preventing, so exercise extreme caution.
Failure to follow these instructions will result in death or serious injury.
EXPLOSION AND/OR FIRE HAZARD
FROM A REVERSE POLARITY CONNECTION
5. Working on the inverter s negative DC input terminal, attach one end of the negative DC
input cable to the negative DC input terminal on the inverter.
6. Attach the other end of the negative DC input cable to the negative terminal of the
battery If you have installed a battery selector switch, set it to off when making the
connection to prevent sparking.
NOTE: This is last cable connection, A spark is normal when you make the connection to
This section explains how to operate the inverter efficiently and effectively:
Gives procedures for operating the inverter from the front panel
Discusses operating limits and inverter loads
Discusses battery charging frequency
Provides information about routine maintenance
Note: The inverter's output power efficiency is different when input voltage is different.
10.1 TURNING THE INVERTER ON AND OFF
The ON/OFF switch on the inverter s front panel is the main ON/OFF switch that turns the
control circuit in the inverter on and off.
To turn the inverter on and off from its front panel:
Move the ON/OFF switch to the ON position to turn the inverter on.
Move the ON/OFF switch to the OFF position to turn the inverter off.
When switch is off, the inverter draws a very low current from the battery.
To turn the inverter on and off from the remote switch:
Make sure the main ON/OFF switch on the front panel is turned ON.
Move the remote ON/OFF switch to the ON position to turn the inverter ON.
Move the remote ON/OFF switch to the OFF position to turn the inverter OFF.
When the remote switch is off, the inverter draws a very low current from the battery.
The inverter draws a current from the battery with the main ON/OFF switch turned
on and no load connected. If the main switch is left on, even with no loads the inverter will
eventually discharge the battery. To prevent unnecessary battery discharge, turn the
inverter off when you are not using it.
10. INVERTER OPERATION
ELECTRICAL SHOCK HAZARD
The inverter
'
s ON/OFF switch does not disconnect DC battery power from the inverter. You must disconnect
AC and DC power before working on any circuits connected to the inverter.
Failure to follow these instructions can result in death or serious injury.
the battery without a battery selector switch. If you have installed a battery selector
switch, use it to select one