GVP 2221315 Скачать руководство пользователя страница 6

9.4 CONNECT THE DC CABLE

IMPORTANT:  Before  proceeding,  make  sure  that  your  DC  input  cables  are  properly 

terminated  with ring connectors  appropriate  for the size of the cable you are using.  We 

advise you use the DC input cable inside of our inverters packing.

1. Make sure the inverter's ON/OFF switch is in the off position

2. Working on the inverter's positive DC input terminal first, attach one end of the positive 

DC input cable to the positive DC input terminal on the inverter.

IMPORTANT: Do not over tighten the nut on the inverter terminal. Damage to the inverter 

terminal  may  result.  However,  loose  connections  can  cause  excessive  voltage  drop  and 

may cause overheated wires and melted insulation.

3.  Attach  a  fuse  holder  (with  an  installed  fuse)  to  the  other  end  of  the  positive  battery 

cable.

Alternatively,  if  you  using  a  circuit  breaker,  install  the  circuit  breaker  on  the  positive 

terminal of the battery.

4.  Attach  the  fused  end  on  the  positive  DC  input  cable  to  the  positive  terminal  of  the 

battery.

Alternatively,  if  you  are  using  a  circuit  breaker,  attach  the  other  end  of  the  positive  DC 

input cable to the circuit breaker on the battery.

DC power connection to the inverter must be positive to positive and negative to negative.

A reverse polarity connection (connecting positive to negative) will blow the internal fuse inside the inverter 

and can cause damage to the inverter.

Damage caused by a reverse polarity connection is not covered by the warranty.

Failure to follow these instructions can damage the unit and or damage other equipment.

Thoroughly ventilate the battery compartment before proceeding to connect the negative DC input cable to 

the battery.

It is always possible that flammable fumes are preventing, so exercise extreme caution.

Failure to follow these instructions will result in death or serious injury.

EXPLOSION AND/OR FIRE HAZARD

FROM A REVERSE POLARITY CONNECTION

5. Working on the inverter s negative DC input terminal, attach one end of the negative DC 

input cable to the negative DC input terminal on the inverter.

6.  Attach  the  other  end  of  the  negative  DC  input  cable  to  the  negative  terminal  of  the 

battery  If  you  have  installed  a  battery  selector  switch,  set  it  to  off  when  making  the 

connection to prevent sparking.

NOTE: This is last cable connection,  A spark is normal when you make the connection  to 

This section explains how to operate the inverter efficiently and effectively:

     Gives procedures for operating the inverter from the front panel

     Discusses operating limits and inverter loads

     Discusses battery charging frequency

     Provides information about routine maintenance

Note: The inverter's output power efficiency is different when input voltage is different.

10.1 TURNING THE INVERTER ON AND OFF

The ON/OFF switch on the inverter s front panel is the main ON/OFF switch that turns the 

control circuit in the inverter on and off.

To turn the inverter on and off from its front panel:

     Move the ON/OFF switch to the ON position to turn the inverter on.

     Move the ON/OFF switch to the OFF position to turn the inverter off.

When switch is off, the inverter draws a very low current from the battery.

To turn the inverter on and off from the remote switch:

     Make sure the main ON/OFF switch on the front panel is turned ON.

     Move the remote ON/OFF switch to the ON position to turn the inverter ON.

     Move the remote ON/OFF switch to the OFF position to turn the inverter OFF.

When the remote switch is off, the inverter draws a very low current from the battery.

The inverter draws a current from the battery with the main ON/OFF switch turned

on and no load connected. If the main switch is left on, even with no loads the inverter will

eventually  discharge  the  battery.  To  prevent  unnecessary  battery  discharge,  turn  the 

inverter off when you are not using it.

10. INVERTER OPERATION

ELECTRICAL SHOCK HAZARD

     

The inverter

'

s ON/OFF switch does not disconnect DC battery power from the inverter. You must disconnect 

AC and DC power before working on any circuits connected to the inverter.

Failure to follow these instructions can result in death or serious injury.

the  battery  without  a  battery  selector  switch.  If  you  have  installed  a  battery  selector 

switch, use it to select one

Содержание 2221315

Страница 1: ...2221315 Inverter ...

Страница 2: ...ubstandard wiring Make sure that all wiring is in good condition and is not undersized ELECTRICAL SHOCK HAZARD FIRE AND BURN HAZARD EXPLOSION HAZARD Failure to follow these instructions will result in death or serious injury Do not cover or obstruct the air intake vent openings and or install in a zero clearance compartment Do not use transformer less battery chargers in conjunction with the inver...

Страница 3: ... protects the battery from being completely discharged HIGH BATTERY VOLTAGE SHUTDOWN Shuts the inverter down automatically if the input voltage rises to 31 volts or more OVER LOAD SHUTDOWN Shuts the inverter down automatically if the loads connected to the inverter exceed the inverter s operating limits OVER TEMPERATURE SHUTDOWN Shuts the inverter down automatically if its internal Temperature ris...

Страница 4: ... indicates the inverter is operating 7 AC OUTLETS are used to power loads 8 USB port it output DC5V 2 1A for charge for your appliance 9 ON OFF SWITCH turns the Inverter on and off 10 Remote ON OFF connector port is used for connecting the ON OFF remote switch 5 2 POWER SYSTEM CONNECTION EXAMPLE Figure 4 Typical power system designs 5 3 BATTERY REQUIREMENTS Battery type and battery size strongly a...

Страница 5: ...rs on the positive cable line in your power system following these recommendations when you purchasing fuses or circuit breakers Select a fuse or circuit breaker with a maximum rating of 150Adc Determine the short circuit current rating of the battery and choose a battery fuses that withstand the short circuit current that may be generated by the battery 9 INSTALL THE INVERTER Review and follow th...

Страница 6: ...e negative DC input terminal on the inverter 6 Attach the other end of the negative DC input cable to the negative terminal of the battery If you have installed a battery selector switch set it to off when making the connection to prevent sparking NOTE This is last cable connection A spark is normal when you make the connection to This section explains how to operate the inverter efficiently and e...

Страница 7: ...Some induction motors used in freezers pumps and other motor operated equipment require high surge currents to start The inverter may not be able to start some of these motors even though their rated current draw is within the inverter s limits The inverter will normally start single phase induction motors Some equipment may be not work well or damaged by the inverter s modified sine wave output S...

Страница 8: ...na provides an adequate snow free signal and that you are using good quality cable between the antenna and the television 3 Keep the cables between the battery and the inverter as short as possible and twist them together with two to three twists per foot this minimizes radiated interference from the cables Move the television as far away from the inverter as possible Do not operate high power loa...

Страница 9: ...ed by damage may adversely affect human health and harm the environment during recycling WARRANTY CARD 19 WARRANTY AND SERVICE AGREEMENTS This warranty covers only manufacturing defects The appliance must not be modified or altered in any way with regards to both form and function This warranty does not apply in case of improper usage usage that falls beyond normal use as indicated in the user s m...

Отзывы: