Cabling and connectors | Triax adapter connectors
3-14
3.3.13 Auxiliary connector
Figure 3-23. Auxiliary connector
4
1
2
3
5
6
7
8
9
10
11
1.
+5VL
2.
0VL
3.
AN0
4.
AN1
5.
Spare
6.
On-air n.c.
7.
Private Data Camera - Base Station
8.
Ground
9.
Private Data Base Station - Camera
10. Ground
11. Shield
Private data input signals: 0 <0.8 Volt; 1 >2.4 Volt
max. level: +/-12 Volt
input impedance: >100 kOhm
baud rate: 2400 bits/s nom; 4800 bits/s max.
Private data output signals: C-MOS levels 5V
output impedance: <1 kOhm.
Analogue outputs (AN0 and AN1) output level: 0 - 5 Volt
output impedance: 100 Ohm
Fischer 11-pole female; panel view
Panel part number (X109): 3922 040 02512