Cabling and connectors | Configurations
3-2
3.1 Configurations
3.1.1 Camera with Triax adapter
A camera head with an LDK 5430 Triax adapter can be connected to an LDK 4501 Base
Station using a Triax cable. The maximum length of cable that can be used without
significant degradation of the video signal is 3000m (10,000 ft.) for a 14mm Triax
cable. The power supply is applied to the Base Station and via the Triax cable to the
camera. An OCP 400 operational control panel can be connected directly to the Base
Station using a cross-over Ethernet cable.
Figure 3-1. Camera with Triax adapter
Camera Base Station
THOMSON
Clear
ND1/4
ND1/16
ND1/64
Clear
Star 4P
Star 6P
Soft Focus
Smart
card
Power
on
P w
el
Tracker
Aux
1
2
3
4
A
B
C
D
Camera head
Triax adapter
Triax cable
Base Station
Ethernet cable
OCP 400
Power supply
3.1.2 Multiple Triax cameras with C2IP network
Each camera head with an LDK 5430 Triax adapter can be connected to an LDK 4501
Base Station using a Triax cable. The maximum length of cable that can be used
without significant degradation of the video signal is 3000m (10,000 ft.) for a 14mm
Triax cable. The power supply is applied to the Base Station and via the Triax cable to
the camera.
The Base Stations are each connected to a network hub or router via an Ethernet cable
(straight through, not cross-over). The OCP 400 operational control panels and, if
required the MCP 400 Master Control Panel, are also connected to the Ethernet
network via a hub or router.
Optionally, a Series 9000 OCP can be connected directly to a Base Station using a two-
wire bus cable. In this situation no loop-through is available and the camera number
must be set to 1.
Содержание LDK 400
Страница 1: ...User s Guide LDK 400 CAMERA SYSTEM 3922 496 30531 version 1 ...
Страница 6: ...LDK 400 User s Guide vi ...
Страница 19: ...Introduction Specifications 1 7 1 3 1 Dimensions Figure 1 1 Dimensions ...
Страница 78: ...Operating instructions Triax adapter controls 4 32 ...
Страница 90: ...Menu structure Menu structure 5 12 ...