Cabling and connectors | Triax adapter connectors
3-10
3.3.4 Script light power supply socket
Figure 3-13. Script light power supply output connector
3
1
2
1.
+12 Vdc (maximum dissipation 3W)
2.
Power return
3.
Shield
Fischer 3-pole female: panel view (X102)
3.3.5 Teleprompter video output connector
Figure 3-14. Teleprompter video output connector
This socket supplies the 1Vpp teleprompter signal applied
to the Base Station. (This socket has no output if the
reference input socket is used as a return video channel).
BNC connector: panel view (X112)
3.3.6 DC power and tally output socket
Figure 3-15. DC power and tally output connector
4
1
2
3
1.
Ground
2.
On air
3.
No connection
4.
+12 Vdc (max. 18W)
Shield of cable directly to the connector housing.
The socket provides access to an internal tally switch.
When the camera is on-air, the contact of the internal
relay is closed.
Hirose 4-pole female: panel view (X110)