Model GX-7-DI Spray Gun
14
22943-1, Issue 1
d)
Release both triggers and close the Manual Valves on the Service
Block.
e)
Repeat the Procedure for the other side of the Gun.
f)
After the initial cleaning, remove the Air Cap and PCD Retainer and
PCD and flush a second time. (This is done to get a more thorough
cleaning.)
6.
REMOVE THE SERVICE BLOCK OF THE GUN SERVICE KIT FROM THE
GUN– Using the 5/16” Spintite; disconnect the Service Block from the gun.
7.
CLEAN SCREENS, CHECK VALVES AND SCREEN SCREW- Using the Flush
Can, flush out the Screens, Check Valves and the Screen Screw Cavities completely.
See the Screen Screw Removal and Service Procedure section of this manual.
Important: Inspect the Air Cap, PCD, Module, and Gun Block for build up of
material and clean them as required.