30
.............................
CCEC/ OM Manual GlasStile GSR 1.6 EN
07
.2009
Input/output signals
Shielded multi-core cable with conductor area of 0.22mm (min).
1. Strip the sheath to the require length ensuring enough length for the shielding to be
fixed to the terminal.
2. Secure the cable by its sheath in the clamp provided.
3. Connect the shield to the terminal provided.
4. Make all required connections & ensure all cable contained is within the centre column.
Load-relieving clamps on the adjustment plate shall secure the cables as follows:
Fig 5.7 - Electrical Connections
Fig 5.7a
– Cable fixing locations